欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT4280IGU-3-T1 参数 Datasheet PDF下载

AAT4280IGU-3-T1图片预览
型号: AAT4280IGU-3-T1
PDF下载: 下载PDF文件 查看货源
内容描述: 压摆率受控负载开关 [Slew Rate Controlled Load Switch]
分类和应用: 开关
文件页数/大小: 14 页 / 381 K
品牌: AAT [ ADVANCED ANALOG TECHNOLOGY, INC. ]
 浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第6页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第7页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第8页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第9页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第10页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第12页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第13页浏览型号AAT4280IGU-3-T1的Datasheet PDF文件第14页  
AAT4280  
Slew Rate Controlled Load Switch  
For maximum current, refer to the following equation:  
IOUT(MAX) < ( PD(MAX) / RDS)1/2  
reported for 5V can be scaled by the ratio seen in  
the chart to derive the RDS for a 4V VIN: 120mΩ ·  
87mΩ /80mΩ = 130mΩ. De-rated for temperature:  
130mΩ x (1 + 0.0028 · (125°C -25°C)) = 166mΩ.  
The power dissipation for a 100mA load is calculat-  
ed as follows:  
For example, if VIN = 5V, RDS(MAX) = 154mΩ and TA  
= 25°C, IOUT(MAX) = 2.3A. If the output load current  
were to exceed 2.3A or if the ambient temperature  
were to increase, the internal die temperature  
would increase, and the device would be damaged.  
2
PD(MAX) = IOUT · RDS  
PD(100mA) = (100mA)2 · 166mΩ  
PD(100mA) = 1.66mW  
Higher peak currents can be obtained with the  
AAT4280. To accomplish this, the device thermal  
resistance must be reduced by increasing the heat  
sink area or by operating the load switch in a duty-  
cycle manner.  
PD(87.5%D/C) = %DC · PD(100mA)  
PD(87.5%D/C) = 0.875 · 1.66mW  
PD(87.5%D/C) = 1.45mW  
The power dissipation for 100mA load at 87.5%  
duty cycle is 1.45mW. Now the power dissipation  
for the remaining 12.5% of the duty cycle at 2A is  
calculated:  
High Peak Output Current Applications  
Some applications require the load switch to oper-  
ate at a continuous nominal current level with short  
duration, high-current peaks. The duty cycle for  
both output current levels must be taken into  
account. To do so, first calculate the power dissi-  
pation at the nominal continuous current level, and  
then add in the additional power dissipation due to  
the short duration, high-current peak scaled by the  
duty factor.  
2
P
D(MAX) = IOUT · RDS  
PD(2A) = (2A)2 · 166mΩ  
PD(2A) = 664mW  
PD(12.5%D/C) = %DC · PD(2A)  
PD(12.5%D/C) = 0.125 · 664mW  
PD(12.5%D/C) = 83mW  
The power dissipation for 2A load at 12.5% duty  
cycle is 83mW. Finally, the two power figures are  
summed to determine the total true power dissipa-  
tion under the varied load.  
For example, a 4V system using an AAT4280 oper-  
ates at a continuous 100mA load current level and  
has short 2A current peaks, as in a GSM applica-  
tion. The current peak occurs for 576µs out of a  
4.61ms period.  
PD(total) = PD(100mA) + PD(2A)  
PD(total) = 1.45mW + 83mW  
PD(total) = 84.5mW  
First, the current duty cycle is calculated:  
The maximum power dissipation for the AAT4280  
operating at an ambient temperature of 85°C is  
333mW. The device in this example will have a  
total power dissipation of 84.5mW. This is well  
within the thermal limits for safe operation of the  
device; in fact, at 85°C, the AAT4280 will handle a  
2A pulse for up to 50% duty cycle. At lower ambi-  
ent temperatures, the duty cycle can be further  
increased.  
% Peak Duty Cycle: X/100 = 576µs/4.61ms  
% Peak Duty Cycle = 12.5%  
The load current is 100mA for 87.5% of the 4.61ms  
period and 2A for 12.5% of the period. Since the  
Electrical Characteristics do not report RDS(MAX) for  
4V operation, it must be calculated approximately  
by consulting the chart of RDS(ON) vs. VIN. The RDS  
4280.2006.11.1.4  
11