 浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第1页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第2页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第3页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第4页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第6页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第7页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第8页浏览型号AAT3688IWP-4.2-T1的Datasheet PDF文件第9页  
AAT3688  
USB Port Lithium-Ion/Polymer Battery Charger  
Electrical Characteristics1  
VADP = 5V, TA = -25°C to +85°C, unless otherwise noted. Typical values are at TA = 25°C.  
Symbol Description  
Conditions  
Min Typ Max Units  
Logic Control / Protection  
VUSBSEL(H) Input High Threshold  
VUSBSEL(L) Input Low Threshold  
1.6  
1.6  
V
V
0.4  
VEN(H)  
VEN(L)  
VSTAT  
ISTAT  
Input High Threshold  
V
Input Low Threshold  
0.4  
0.4  
V
Output Low Voltage  
STAT Pin Sinks 4mA  
V
STAT Pin Current Sink Capability  
Over-Voltage Protection Threshold  
8.0  
4.4  
10  
mA  
V
VOVP  
For USBH Mode  
For USBL Mode  
For USBH Mode  
For USBL Mode  
ITK/ICHG  
Pre-Charge Current  
%
50  
ITERM/ICHG Charge Termination Threshold Current  
ITERM/ICHG Charge Termination Threshold Current  
7.5  
35  
%
%
ITS  
Current Source from TS Pin  
70  
80  
90  
µA  
Threshold  
310 330  
15  
350  
TS1  
TS Hot Temperature Fault  
mV  
Hysteresis  
Threshold  
2.2 2.3  
10  
2.4  
0.4  
V
mV  
mA  
V
TS2  
TS Cold Temperature Fault  
Hysteresis  
I_DATA  
VDATA(H)  
VDATA)(L)  
SQPULSE  
tPERIOD  
fDATA  
DATA Pin Sink Current  
DATA Pin is Active Low State  
3.0  
Input High Threshold  
1.6  
Input Low Threshold  
V
Status Request Pulse Width  
System Clock Period  
Status Request  
200  
50  
ns  
µs  
kHz  
°C  
Data Output Frequency  
Over-Temperature Shutdown Threshold  
20  
TOVSD  
145  
1. The AAT3688 output charge voltage is specified over the 0° to 70°C ambient temperature range; operation over the -25°C to +85°C  