AAT3258
300mA LDO Linear Regulator with µP Reset
Electrical Characteristics
1
T
A
= 25°C, unless otherwise noted.
Symbol
Description
Conditions
T
A
= 0°C to +70°C
T
A
= -40°C to +85°C
V
CC
= 5.5V
V
CC
= 3.0V
V
DET
= 3.0V
V
DET
> V
TH
AAT3258xxx-x.x-R
T
A
= 25°C
AAT3258xxx-x.x-Y
V
DET
= V
TH
to (V
TH
- 100mV)
150
10
30
Min
1
1.2
Typ
Max
5.5
5.5
3.0
2.0
2.0
1.0
2.67
2.49
Units
Microprocessor Reset Monitor
V
DET
I
Q
I
DD
I
DOFF
V
TH
∆V
TH
/°C
T
P
T
RDY
T
MR
MRGI
R
MR
T
MD
V
IH
V
IL
V
OL
Input Voltage Range
Quiescent Current
Operating Supply Current
Reset Leakage Current
Reset Threshold Voltage
RESET Threshold Tempco
Reset Propagation Delay
Reset Active Timeout Period
MR Minimum Pulse Width
MR Glitch Immunity
MR Pull-Up Resistance
MR to Reset Propagation
Delay
MR Input Threshold (high)
MR Input Threshold (low)
V
µA
µA
µA
V
ppm/°C
µs
ms
µs
ns
kΩ
µs
0.25
×
V
DET
0.3
V
0.4
V
V
1.05
0.85
0.85
2.59
2.41
2.63
2.45
40
15
250
100
65
0.5
400
90
Reset Low Voltage
V
OH
Reset High Voltage
V
DET
= V
TH(MAX)
0.7
×
V
DET
V
DET
= V
TH(MAX)
I
SINK
= 1.2mA, V
DET
= V
TH(MIN)
,
V
TH
≤
3.08V, Reset Asserted
I
SINK
= 3.2mA, V
DET
= V
TH(MIN)
,
V
TH
>
3.08V, Reset Asserted
I
SOURCE
= 800µA, V
DET
> 3.08V,
V
DET
- 1.5
V
DET
> V
TH(MAX)
I
SOURCE
= 500µA, V
DET
>
0.8 * V
DET
V
TH(MAX)
, V
TH
≤
3.08V
V
1. The AAT3258 is guaranteed to meet performance specifications over the -40°C to 85°C operating temperature range and is assured
by design, characterization, and correlation with statistical process controls.
3258.2006.03.1.6
5