IMP1834/A/D  
Application Information  
Operation – Power Monitor  
Reset Signal Polarity and Output Stage Structure  
The IMP1834 supervisors simultaneously detect out-of-tolerance The IMP1834 and IMP1834A supervisors have active LOW reset  
power supply conditions on both 3.3V and 5V power supplies. If signals. The IMP1834D reset outputs are active HIGH.  
the voltages at 5V or 3.3V are outside the tolerance band, the  
IN  
IN  
The IMP1834 and IMP1834D have CMOS push-pull output  
stages. The IMP1834A has open drain reset outputs.  
reset for the failing supply voltage becomes active. When the moni-  
tored supply returns to an in-tolerance state, the reset remains active  
for approximately 350ms before returning to the inactive state.  
Output Stage  
Configuration  
IMP Part  
RESET Polarity  
On power-up, the reset signals are kept active for approximately  
350ms after the power supply voltages have reached the selected  
tolerance. This allows the power supply and microprocessor to  
stabilize before the reset is removed.  
IMP1834  
LOW  
LOW  
LOW  
LOW  
LOW  
LOW  
HIGH  
HIGH  
HIGH  
Push-Pull  
Push-Pull  
Push-Pull  
Open Drain  
Open Drain  
Open Drain  
Push-Pull  
Push-Pull  
Push-Pull  
IMP1834EMA  
IMP1834S  
IMP1834A  
All supply current for the IMP1834 devices is drawn from the  
IMP1834AEMA  
IMP1834AS  
IMP1834D  
input (5VIN or 3.3V ) with the highest voltage level. The outputs  
IN  
draw current from their input supplies 5VIN and 3.3VIN  
.
IMP1834DEMA  
IMP1834DS  
tR  
V
INTP (Max)  
Trip Point Tolerance Selection  
V
INTP  
VINTP (Min)  
The 3.3VTOL and 5VTOL inputs allow independent selection of  
the reset trip points. If 5VTOL is connected to the 5V supply input,  
a 10% tolerance is selected. If 5VTOL is grounded, a 5% tolerance  
is selected.  
VIN  
tRPU  
If 3.3VTOL is connected to the 3.3V supply input, a 20% tolerance  
is selected. If 3.3VTOL is grounded, a 10% tolerance is selected.  
See Table 1.  
RESET  
RESET  
VOH  
The 3.3VTOL and 5VTOL tolerance select inputs should be tied to  
ground or to the respective input supply voltage pin, 3.3VIN or 5VIN.  
VOL  
(IMP1834D Only)  
1834_10.eps  
Figure 1. Timing Diagram: Power Up  
tF  
VIN  
VINTP (Max)  
V
INTP  
VINTP (Min)  
> tRPD  
RESET  
RESET Slews  
with VCC  
VOH  
VOL  
RESET  
1834_09.eps  
(IMP1834D Only)  
Figure 2. Timing Diagram: Power Down  
408-432-9100/www.impweb.com  
© 1999 IMP, Inc.  