QDC10 - Multiplex Data on Battery Power Lines  
3.5.3  
Data from QDC10 to Host  
When QDC10 device receives a message from the DC-BUS, data errors are corrected and sent to the  
Host via a synchronous protocol. A header byte indicates the Host of a data transfer. The following table  
describes the formats of data transferred to the Host.  
Table 3.2 - Device response header  
Header  
RxData  
Code  
Fxh  
40h  
Description  
Receive the following 16-x bytes of Data  
Message transmission completed  
TxAck  
TxWakeAck  
Reset  
Sleep  
40h  
01h  
Message transmission completed  
Reset operation was performed  
02h  
04h  
The device entered to Sleep mode  
Corrupted message received. (Would not be transferred to Host)  
RxError  
For the value of x - see table 3.3  
Table 3.3 - Transmit/Receive number of data bytes conversion table  
bytes  
x
Notice:  
-
2
3
4
5
6
7
9
8
8
9
7
10  
6
11  
5
12  
4
13  
3
14  
2
15  
1
16  
0
F
E
D
C
B
A
1. The Host has to begin reading data from the QDC10 within 2mS after the rise of DataOut and finish  
reading it within 10mS in order not to miss a new message on the DC-BUS.  
2. Device responds to Reset and Sleep within 30uS after the command is received. In such case  
DataOut rises for byte transfer very quickly. The device responds to Tx command (TxAck) within 30mS.  
3. Host has to read device response (Reset, Sleep, TxAck, etc.) within 2mS, otherwise the device may  
miss a new message.  
4. Transmit of one byte (RxData=FFh) is an illegal command.  
4
SIGNALS  
Device signals are defined in table 4.1.  
Table 4.1 - Device signals  
Signal Name  
DataIn  
I/O  
I
Description  
Serial Data input (for transmission)  
Serial Data output  
Pin  
6
DataOut  
ClockIn  
TxData  
O
I
13  
12  
7
Synchronous data transfer Host Clock  
Transmit signal  
Received signal  
O
I
RxData  
TxEnable  
~Reset  
17  
8
O
I
When high, Transmit signal is enabled  
Reset device  
4
RxEnable  
OscIn  
O
I
When high, Receive signal is enabled  
Crystal In  
Crystal Out  
2
16  
15  
18  
OscOut  
Res6  
Other I/O  
O
I
SSI Operation – connect to Ground  
Application dependent  
© 2002-2010 YAMAR Electronics Ltd.  
5
DS-QDC10 R1.5  
www.yamar.com  
Shimon Hatarsi Tel Aviv, Israel. Tel (972) 3 5445294 Fax (972) 3 5445279