DCH5048S05 参数 Datasheet PDF下载

DCH5048S05图片预览
型号: DCH5048S05
PDF下载: 下载PDF文件 查看货源
内容描述: 型DC-DC大功率 [DC-DC High Power]
分类和应用:
文件页数/大小: 2 页 / 87 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号DCH5048S05的Datasheet PDF文件第2页  
D C - D C Hig h P o w e r  
5 0 - 2 0 0 Wa tts  
D C H S e rie s  
TH E XP ERTS IN P O W ER  
Up to 8 9 % Effic ie n c y  
-4 0 °C O p e ra tio n  
Hig h Re lia b ility  
In d u s try S ta n d a rd Pa c ka g e  
O ve rc u rre n t P ro te c tio n  
-4 0 % to + 1 0 % Ad ju s tm e n t  
2 :1 In p u t Vo lta g e Ra n g e  
S p e c ific a tio n  
In p u t  
G e n e ra l  
Efficiency  
Isolation  
Input Voltage  
18-36 VDC, 36-76 VDC  
See Tables  
79-89% (See Tables)  
1500 VDC Input to Output  
1500 VDC Input to Ground  
500 VDC Output to Ground  
O u tp u t  
Output Voltage  
Switching Frequency  
Heatsinks  
370 kHz (310 kHz DCH50)  
Contact Sales  
Output Voltage  
Adjustment  
60-110% (60-105% for input of  
36-40 VDC & 18-20 VDC)  
Minimum Load  
Start Up Delay  
Initial Set Accuracy  
Drift  
No minimum load required  
200 ms max (nom Vin & 100% load)  
-3/+5% typically  
En viro n m e n ta l  
Operating  
-40 °C to +100 °C baseplate  
-40 °C to +100 °C  
Temperature  
±0.9% max  
Storage  
Line Regulation  
Load Regulation  
Ripple & Noise  
See Table  
Temperature  
See Table  
Humidity  
20-95% RH non-condensing  
9000 m  
200-250 mV pk-pk depending on  
model 20 MHz bandwidth  
Operating Altitude  
Shock  
20 G, 11 ms once each  
along X, Y & Z axis  
Overvoltage  
Protection  
See Table recycle input to reset  
Vibration  
5 G 10-55 Hz  
3 mins period for 60 mins each  
along X, Y & Z axis  
Overcurrent  
Protection  
Operates at >105% of rated current  
auto recovery  
Overtemperature  
Protection  
Baseplate >+100 °C thermal protection  
is activated & output voltage is  
shutdown, after cooling recycle  
input to reset  
EM C & S a fe ty  
Emissions  
EN55022 Level B conducted  
EN55022 Level B radiated  
External components required  
Contact Sales for Application Note  
Temperature  
Coefficient  
±0.03%/°C max  
Remote Sense  
Compensates for 0.3 V line drop max,  
when not used the remote sense  
terminals must be connected locally  
ESD Susceptibility  
EN61000-4-4 Level 2  
EN61000-4-3 Level 3  
Radiated  
Susceptibility  
Remote ON/OFF  
Negative logic L: (or short) ON,  
H: (or open) OFF  
(for positive logic add suffix ‘-R’ to  
EFT/Burst  
Surge  
EN61000-4-4 Level 3  
EN61000-4-5 Level 3  
UL1950, c-UL, EN60950  
model number)  
Safety Approvals  
w w w .xp p lc .c o m  