C o m p o n e n t P o w e r D C - D C M o d u le s  
5 0 - 7 0 0 Wa tts  
TH E XP ERTS IN P O W ER  
C P M S e rie s  
Lo w P ro file  
In d u s try S ta n d a rd Fo o tp rin t  
W id e O p e ra tin g Te m p e ra tu re  
Pa ra lle l O p e ra tio n  
Re m o te O N/O FF  
Ad ju s ta b le O u tp u t  
O ve rvo lta g e & O ve rlo a d P ro te c tio n  
S p e c ific a tio n  
In p u t  
G e n e ra l  
Efficiency  
Isolation  
Input Voltage  
18-36 VDC  
36-76 VDC  
45-160 VDC  
88-370 VDC  
200-400 VDC  
(see tables)  
Up to 89% dependant on model  
3 kVAC Input to Output  
2 kVAC Input to Baseplate  
500 VDC Output to Baseplate  
Switching Frequency  
Parallel Operation  
500 kHz - CPM50 & 100  
370 kHz - CPM150, CPM200, 400 & 600  
Current share pin provided on all  
except 50 W models, derate max  
O u tp u t  
Output Voltage  
See Tables  
current by 10% per module  
Output Voltage  
Adjustment  
±10% CPM50 & 100,  
60-110% CPM150 ,CPM200 &  
CPM400, 80-110% CPM600  
En viro n m e n ta l  
Operating  
-10 °C to +85°C CPM50 & CPM100,  
-20 °C to +85°C CPM150, CPM200,  
CPM400 & CPM600 (baseplate)  
Minimum Load  
Start Up Delay  
Initial Set Accuracy  
Drift  
No minimum load required  
200 ms max (100% load)  
±4.0% max  
Temperature  
Storage  
-40 °C to +85 °C  
±0.5% max  
Temperature  
Line Regulation  
Load Regulation  
Ripple & Noise  
±0.5% max  
Relative Humidity  
Shock  
20-95% non-condensing  
±0.9% max  
20 G for 11 ms once each along  
X, Y & Z axis  
200 mV pk-pk (0°C to +85°C)  
Vibration  
10-55 Hz 5 G for 3 min periods,  
over 60 mins along each X, Y & Z axis  
Overload  
Protection  
Operates at >105% of rated current,  
recovers automatically  
Overvoltage  
Protection  
Operates at between 115-140% of  
rating recycle input to reset  
S a fe ty  
Emissions  
EN55022 Level A conducted  
EN55022 Level A radiated  
Remote Sense  
Compensates for 300mV min  
if not required then sense connections  
must be made locally ie +S to +Vout  
and -S to -Vout  
Contact sales for Application Note  
ESD Susceptibility  
EN61000-4-2 Level 2  
Remote ON/OFF  
Standard on all models  
Radiated  
Susceptibility  
EN61000-4-3 Level 3  
EN61000-4-4 Level 3  
EN61000-4-5 Level 3  
EFT/Burst  
Surge  
Safety Approvals  
UL1950, C-UL, EN60950, VDE0160  
IEC950  
w w w .xp p lc .c o m  