AC - D C O p e n Fra m e
1 0 0 - 2 2 5 Wa tts
C P L S e rie s
TH E XP ERTS IN P O W ER
Is o la te d O u tp u ts
•
•
Hig h Pe a k C u rre n t Ra tin g s
•
C o m p a c t P C B C o n s tru c tio n
•
O p tio n a l Re m o te O n /O ff
•
Ad ju s ta b le O u tp u t Vo lta g e
•
EN5 5 0 2 2 Le ve l B
•
C o ve r, C o n n e c to r & Lo o m Kits Ava ila b le
S p e c ific a tio n
In p u t
Options
•
Designated by the following suffixes to
the model number:
Reduce leakage current <0.1 mA ‘-G’
Remote ON/OFF ‘-R’
Cover fitted ‘-C’
Screw terminals ‘-T’
Input Voltage
•
•
•
85-264 VAC (120-370 VDC)
47-63 Hz
Input Frequency
Inrush Current
15/30 A at 120/230 VAC in,
100% load & 25 °C
Add 4 outputs by the addition of a
DC-DC converter to the board ‘-Z’
Power Factor
•
•
0.99 typical at 100 VAC, 0.93 typical at
200 VAC & 100% load to IEC61000-3-2
Contact Sales Office
Earth Leakage
Current
0.75 mA max at 230 VAC 60 Hz
En viro n m e n ta l
Operating
O u tp u t
•
•
-10 °C to +70 °C (See Derating Curve)
-20 °C to +75 °C
Output Voltage
•
•
See Tables
Temperature
Output Voltage
Adjustment
±10% V1 only
Storage
Temperature
Minimum Load
Start Up Time
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
•
•
•
•
•
•
•
No minimum load required
Humidity
Shock
•
•
20-90% RH, non condensing
196.1 m/s2 (20 G), 11 ms once each
X, Y & Z axis
V1 250 ms, V2 500ms
V1 40 ms, V2 20 ms at 120 VAC
0.4% max over specified input range
0.8% max for a 100% load change
150 mV pk-pk max (0 °C to +50 °C)
Vibration
•
2 G 10-55 Hz, 3 axis
EM C & S a fe ty
Emissions
•
•
•
EN55022 Level B conducted
EN55022 Level B radiated
Overcurrent
Protection
>105% of rated current on V1 & >101%
of peak current on V2 auto recovery
ESD Susceptibility
EN61000-4-2 Level 2 contact
Level 3 air
Overvoltage
Protection
•
>115% of nominal value for V1 &
115-140% of nominal value for V2
Radiated
Susceptibility
EN61000-4-3 Level 3
G e n e ra l
Efficiency
•
•
74-83% depending on specific model
EFT/Burst
Surge
•
•
EN61000-4-4 Level 3
Isolation
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
V1 to V2 100 VAC 1 min,
cut off current 100 mA,
100 VDC 10 MΩ min
EN61000-4-5 Level 3 line to line
Level 4 line to ground
Safety Approvals
•
UL1950, C-UL, EN60950, VDE0160
Switching Frequency
•
80-500 kHz
•
•
w w w .xp p lc .c o m
s a le s @xp p lc .c o m