AC - D C O p e n Fra m e  
1 0 0 - 2 2 5 Wa tts  
C P L S e rie s  
TH E XP ERTS IN P O W ER  
Is o la te d O u tp u ts  
Hig h Pe a k C u rre n t Ra tin g s  
C o m p a c t P C B C o n s tru c tio n  
O p tio n a l Re m o te O n /O ff  
Ad ju s ta b le O u tp u t Vo lta g e  
EN5 5 0 2 2 Le ve l B  
C o ve r, C o n n e c to r & Lo o m Kits Ava ila b le  
S p e c ific a tio n  
In p u t  
Options  
Designated by the following suffixes to  
the model number:  
Reduce leakage current <0.1 mA -G’  
Remote ON/OFF -R’  
Cover fitted -C’  
Screw terminals ‘-T’  
Input Voltage  
85-264 VAC (120-370 VDC)  
47-63 Hz  
Input Frequency  
Inrush Current  
15/30 A at 120/230 VAC in,  
100% load & 25 °C  
Add 4 outputs by the addition of a  
DC-DC converter to the board -Z’  
Power Factor  
0.99 typical at 100 VAC, 0.93 typical at  
200 VAC & 100% load to IEC61000-3-2  
Contact Sales Office  
Earth Leakage  
Current  
0.75 mA max at 230 VAC 60 Hz  
En viro n m e n ta l  
Operating  
O u tp u t  
-10 °C to +70 °C (See Derating Curve)  
-20 °C to +75 °C  
Output Voltage  
See Tables  
Temperature  
Output Voltage  
Adjustment  
±10% V1 only  
Storage  
Temperature  
Minimum Load  
Start Up Time  
Hold Up Time  
Line Regulation  
Load Regulation  
Ripple & Noise  
No minimum load required  
Humidity  
Shock  
20-90% RH, non condensing  
196.1 m/s2 (20 G), 11 ms once each  
X, Y & Z axis  
V1 250 ms, V2 500ms  
V1 40 ms, V2 20 ms at 120 VAC  
0.4% max over specified input range  
0.8% max for a 100% load change  
150 mV pk-pk max (0 °C to +50 °C)  
Vibration  
2 G 10-55 Hz, 3 axis  
EM C & S a fe ty  
Emissions  
EN55022 Level B conducted  
EN55022 Level B radiated  
Overcurrent  
Protection  
>105% of rated current on V1 & >101%  
of peak current on V2 auto recovery  
ESD Susceptibility  
EN61000-4-2 Level 2 contact  
Level 3 air  
Overvoltage  
Protection  
>115% of nominal value for V1 &  
115-140% of nominal value for V2  
Radiated  
Susceptibility  
EN61000-4-3 Level 3  
G e n e ra l  
Efficiency  
74-83% depending on specific model  
EFT/Burst  
Surge  
EN61000-4-4 Level 3  
Isolation  
3000 VAC Input to Output  
2000 VAC Input to Ground  
500 VAC Output to Ground  
V1 to V2 100 VAC 1 min,  
cut off current 100 mA,  
100 VDC 10 Mmin  
EN61000-4-5 Level 3 line to line  
Level 4 line to ground  
Safety Approvals  
UL1950, C-UL, EN60950, VDE0160  
Switching Frequency  
80-500 kHz  
w w w .xp p lc .c o m  