AC-DC Chassis Mount  
600-1000 Watts  
CPK Series  
TH E XPE R T S IN PO W E R  
Up to 2 kW Peak Rating  
Wide Output Voltage Adjustment  
Up to 500 W Convection Cooled  
Optional Conformal Coating  
Optional Remote ON/OFF  
Optional AC, DC & Fan Fail Signals  
Specification  
Input  
Input Voltage  
Input Frequency  
Inrush Current  
Power Factor  
Switching  
Frequency  
85 kHz ±15% active PFC  
130 kHz ±15% forward converter  
85-264 VAC (120-350 VDC)  
47-63 Hz  
Vertical  
Terminal block  
Add suffix ‘-T’ to model numbers  
20/40 A typical at 115/230 VAC  
0.98 typical at 230 VAC at 100% load  
Din Rail Mounting  
Fan Fitted  
Add suffix ‘-NI’ to model numbers  
Add suffix ‘-F’ to model number  
(only available on 24 V units)  
Earth Leakage Current •  
0.75 mA max at 230 VAC 60Hz  
for 0.50 mA add suffix ‘-E’,  
for 0.15 mA add suffix ‘-G’  
N+1 Operation  
Option -W’ & external oring diodes  
Alarms (Optional)  
For AC fail, DC fail and fan fail add  
suffix ‘-W’ to model number  
Output  
Output Voltage  
Conformal Coating  
Add suffix ‘-Lto model numbers  
See Table  
See Table  
Output Voltage  
Adjustment  
Environmental  
Operating  
Temperature  
-10 °C to +70 °C (fan cooled)  
Derate linearly above +50 °C to 60%  
load at +70 °C.  
For convection cooled rating - See  
Derating Curves  
Minimum Load  
Start Up time  
Hold Up time  
Initial Set Accuracy  
Drift  
No minimum load required  
500 ms max at 100 VAC 100% load  
20 ms typical at 100 VAC 100% load  
±1% max  
±0.4%  
Storage Temperature  
Relative Humidity  
Shock  
-20 °C to +75 °C  
Line Regulation  
Load Regulation  
Ripple & Noise  
±0.4% from low line to high line  
±0.7% max from 0-100% load  
±0.8% max pk-pk 20 MHz bandwidth  
20-90% RH non-condensing  
20 G, 11 ms once each, X, Y & Z axis  
2 G, 3 min period, 60 min each along  
X, Y & Z axis  
Vibration  
Overvoltage  
Protection  
115-140% of Vnom, recycle input to  
restart  
Overcurrent  
Protection  
101% of peak current auto recovery  
EMC & Safety  
Emissions  
EN55022 level B conducted  
(level A with option E not available with  
option G) EN55022 level B radiated  
Remote ON/OFF  
(Optional)  
Add suffix ‘-R’ to model number  
ON 4.5-12.5 V (open circuit)  
between RC+ and RC-  
OFF 0 to 0.5 V (short circuit)  
between RC+ and RC-  
ESD Susceptibility  
EN61000-4-2 Level 2 contact Level 3 air  
EN61000-4-3 Level 3  
Radiated  
Susceptibility  
EFT/Burst  
Surge  
EN61000-4-4 Level 4  
General  
Efficiency  
Isolation  
EN61000-4-5 Level 3 line to line  
Level 4 line to ground  
86-89% dependent on model  
3000 VAC Input to Output  
2000 VAC Input to Ground  
Safety Approvals  
UL60950, C-UL (CSA60950),  
EN60950, EN50178  