OUTPUT VOLTAGE & CURRENT RATINGS
CPC
Output
Power
15 W
15 W
30 W
30 W
60 W
60 W
Output Ratings
Model
Number
Output 1(1)
Output 2(2)
Output 3(2)
+5 V @ 2.0 A (3.0 A pk)
+5 V @ 2.0 A (3.0 A pk)
+5 V @ 3.0 A (4.5 A pk)
+5 V @ 3.0 A (4.5 A pk)
+5 V @ 5.0 A (7.0 A pk)
+5 V @ 5.0 A (7.0 A pk)
+12 V @ 0.3 A (0.6 A pk)
+15 V @ 0.3 A (0.6 A pk)
+12 V @ 1.2 A (2.0 A pk)
+15 V @ 1.0 A (2.0 A pk)
+12 V @ 2.5 A (3.5 A pk)
+15 V @ 2.0 A (3.5 A pk)
-12 V @ 0.2 A (0.30 A pk)
-15 V @ 0.2 A (0.30 A pk)
-12 V @ 0.3 A (0.45 A pk)
-15 V @ 0.3 A (0.45 A pk)
-12 V @ 0.5 A (0.70 A pk)
-15 V @ 0.5 A (0.70 A pk)
CPC15UT1
CPC15UT2
CPC30UT1
CPC30UT2
CPC60UT1
CPC60UT2
Notes
1. Isolated from 2 & 3.
2. Linear regulated..
3. The specified output currents are available for a maximum duration of 10 s if the average current level is below rating and the total
power is below rating for the unit. Outputs 2 & 3 may be loaded to 80ꢀ of their rated current when +5 V is not loaded. ‘FG’
terminal should be used as AC input earth. It is isolated from the DC output.
4. Mating input & output connectors are available. Example: order as CPC30 CON KIT for 30 watt models.
5. Loom kit option: comprising of 2 x 300 mm length cable looms, one terminated with a mating connector for input and the other for
output terminals.
6. Cover option: wrap around chassis & safety cover supplied as a kit or fitted.
•
Operating Characteristics
Mechanical Details - 15 Watt Models
Covered Version
PCB Version
Supplied as cover kit (not fitted). Order as CPC15/COVER KIT
Supplied fitted use suffix C e.g. CPC15UT1-C
Fuse Rating 250 V T2 A
PIN ASSIGNMENT
I/O Connector
Mating Connector (Terminal)
VHR-5N (SVH-21T-1.1
or SVH-21-P1.1)
XHP-8 (BXH-001T-P0.6
or SXH-001T-P0.6)
CN1
CN2
Pin No. Input
CN1
CN2
B3P5-VH
NOTES:
Pin No. Input
2 A per pin maximum for CN2
Weight: 150g or less
1
2
3
4
5
6
7
8
V 1
V 1
G 1
G 1
V 2
G 2
G 2
V 3
1
2
3
4
5
AC(L)
AC(N)
FG
B8B-XH-A
+
1
Tolerance:
Mfr: JST
Dimensions in mm
PWB Material: Glass composite (CEM3)
www.xpplc.com
sales@xpplc.com