AC-DC Chassis Mount
400-650 Watts
CPB600 Series
TH E XPE R T S IN PO W E R
Universal PFC Input
•
•
Low Profile (61mm)
•
Wide Output Voltage Adjustment
•
Remote ON/OFF
•
Power Good Signal
•
Remote Sense
•
Peak Current Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Remote ON/OFF
•
12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
•
•
•
•
•
•
95-264 VAC (120-370 VDC)
47-63 Hz
& the fan
8.2 A max at 115 VAC
40 A max at 230 VAC
0.98/0.95 at 115/230 VAC
0.75 mA max at 230 VAC 60 Hz
General
Efficiency
Isolation
•
•
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
Earth Leakage
Current
Switching Frequency
•
130kHz PFC, 330 kHz PWM
Output
Output Voltage
•
•
See Table
See Table
Environmental
Output Voltage
Adjustment
Operating
•
-20 °C to +70 °C, derate linearly above
+50 °C to 50% at +70°C
Temperature
Minimum Load
Start-Up Time
Hold-up Time
Drift
•
•
•
•
•
•
•
•
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
Storage
•
-20 °C to +75 °C
Temperature
Relative Humidity
Shock
•
•
•
20-90% non condensing
20 G 11 ms, once each x, y and z axis
2 G 10-55Hz for 3 min periods for
60 min along each x, y and z axis
Line Regulation
Load Regulation
Ripple & Noise
±0.5% max
Vibration
±1.0% max 0-100% load
± 1% max pk-pk 20 MHz bandwidth
Overvoltage
Protection
110-130% of Vnom
Recycle input to reset
EMC & Safety
Emissions
•
EN55022 Level B conducted
EN55022 Level A radiated
Overload Protection
•
Operates at 105% of rated current
(101% of pk rating), <5 s auto recovery
>5 s recycle input to reset
ESD
Susceptibility
•
•
EN61000-4-2 Level 2 contact,
Level 3 air
Temperature
Coefficient
•
•
±1.25% max -20 °C to +50 °C
Radiated
EN61000-4-3 Level 3
Susceptibility
Overtemperature
Protection
Operates in the event of fan failure
or if the operating temperature/
derating criteria is exceeded
EFT/Burst
Surge
•
•
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
Remote Sense
•
Compensates for 0.3 V drop max
If not required sense terminals
must be connected locally
Safety Approvals
•
UL60950, C-UL (CSA 60950) EN60950
ie: +S to +M and -S to -M on CN1
•
•
www.xpplc.com
sales@xpplc.com