欢迎访问ic37.com |
会员登录 免费注册
发布采购

CPB1K5PS36 参数 Datasheet PDF下载

CPB1K5PS36图片预览
型号: CPB1K5PS36
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 3 页 / 608 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号CPB1K5PS36的Datasheet PDF文件第2页浏览型号CPB1K5PS36的Datasheet PDF文件第3页  
660 - 1680 Watts  
CPB1K/1K5 Series  
xppower.com  
Universal PFC Input  
Low Profile (61 mm)  
Wide Output Voltage Adjustment  
Remote On/Off  
Power Good Signal  
Remote Sense  
Peak Current Available  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
Inrush Current  
Power Factor  
• 85-264 VAC (120-370 VDC)  
• 47-63 Hz  
Efficiency  
Isolation  
• See tables  
• 3000 VAC Input to Output  
2000 VAC Input to Ground  
500 VAC Output to Ground  
• 19 A at 115 VAC  
• 40 A at 230 VAC  
Switching Frequency  
• 130 ꢀHz PFC, 200 ꢀHz PBꢁ  
• 0.98/0.95 at 115/230 VAC  
Earth Leakage Current • 1.5 mA max at 230 VAC/60Hz  
Environmental  
Operating Temperature • -20 ꢃC to ꢄ70 ꢃC, derate linearly from  
Output  
ꢄ50 ꢃC to 50% at ꢄ70 ꢃC  
Output Voltage  
Output Voltage Trim  
Minimum Load  
Start Up Time  
Hold Up Time  
Drift  
• See tables  
Relative Humidity  
Storage Temperature  
Shock  
• 20-90% non-condensing  
• -20 ꢃC to ꢄ75 ꢃC  
• See tables  
• No minimum load required  
• 400 ms typical at 230 VAC, 100% load  
• 20 ms typical at 100% load  
• 20 G 11 ms, once each x, y and z axis  
Vibration  
• 2 G, 10 Hz to 55 ꢀHz, 3 min periods for 60  
min along each x, y and z axis  
0.4% max  
Line Regulation  
Load Regulation  
Ripple & Noise  
0.5% max  
EMC & Safety  
1.0% max 0-100% load  
1.0% pꢀ-pꢀ, 20ꢁHz ꢂB  
Emissions  
• EN55022, level ꢂ conducted  
EN55022, level A radiated  
Overvoltage Protection • 110-130% Vnom, recycle input to reset  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-4-2, level 2 contact, level 3 air  
• EN61000-4-3, level 3  
Overtemperature  
Protection  
• Operates in the event of fan failure or if  
the operating temperature / derating  
criteria is exceeded  
• EN61000-4-4, level 3  
Surge  
• EN61000-4-5, level 3 line to line,  
level 4 line to ground  
Overload Protection  
• Operates at 105% of rated current (101%  
of pꢀ rating), <5 s auto recovery,  
>5 s recycle input to reset  
Safety Approvals  
• EN60950, UL60950, cUL (CSA 60950)  
Temperature  
Coefficient  
1.25% max -20 ꢃC to ꢄ50 ꢃC  
Remote Sense  
• Compensates for up to 0.3 V drop max  
if not required, sense teminals must be  
connected locally i.e ꢄS to ꢄꢁ and  
-S to -ꢁ on CN1  
Remote On/Off  
• 12 V 3 mA applied between RCG &  
RC2 will inhibit the output of the unit  
and the fan