AC-DC Power Supplies  
CMP250 Series  
250/500 Watts Peak  
• 250 W Convection-cooled Rating  
• 500 W Peak Power  
• IT & Medical Safety (BF) Approvals  
• U Channel 4”x 7.5” Package  
• 80 VAC to 300 VAC Input  
• 5 V/1.5A Standby & 12 V/0.6 A Auxiliary  
• AC OK Signal, Inhibit  
• Current Share  
• 3 Year Warranty  
Dimensions:  
The universal AC input CMP250 provides up to 500 W peak power and 250 W convection-cooled in a  
7.5” x 4” package, over the temperature range -40 °C to +50 °C with derating to +70 °C. Approved for  
IT and Medical (BF) applications and with a feature set including constant current overload  
characteristics, a 5 V/1.5 A standby output, 12 V/0.6 A auxiliary, AC OK signal, inhibit, current share the  
CMP250 is ideal for motors and other electromechanical loads, without the need for fan cooling, in both  
industrial and medical applications.  
CMP250:  
7.50 x 4.00 x 1.57” (190.5 x 101.6 x 39.9 mm)  
CMP250-C:  
7.89 x 4.12 x 1.92” (200.5 x 104.6 x 48.8 mm)  
Models & Ratings  
Output Current V1  
Output Power  
Standby Supply  
V2  
Aux. Supply  
V3  
Output Voltage V1  
Model Number(1)  
Convection  
Peak  
20.8 A  
13.8 A  
10.4 A  
Convection  
250 W  
Peak(2)  
500 W  
500 W  
500 W  
24 V  
36 V  
48 V  
10.4 A  
6.9 A  
5.2 A  
5.0 V / 1.5 A  
5.0 V / 1.5 A  
5.0 V / 1.5 A  
12.0 V / 0.6 A  
12.0 V / 0.6 A  
12.0 V / 0.6 A  
CMP250PS24  
CMP250PS36  
CMP250PS48  
250 W  
250 W  
Notes  
1. Add suffix '-C' for covered version, e.g. CMP250PS24-C (20% derating applies)  
2. Peak current/power available for up to 1 minute. Average power must not exceed 225 W, other peak and average load conditions can be accommodated limited by  
the thermal considerations and average power rating. Peak power and average power derate below 90 VAC.  
Summary  
Characteristic  
Minimum  
Typical  
Maximum  
264  
Units  
Notes & Conditions  
80  
115/230  
Derate output power <90 VAC, see fig.1  
Input Range  
VAC  
300  
0.5 seconds max  
No Load Input Power  
Input Frequency  
1.3  
W
All models, when optional inhibit activated  
47  
50/60  
63  
Hz  
EN61000-3-2 class A compliant  
EN61000-3-2 class C for loads ≥50%  
115/230 VAC. 500 W  
Power Factor  
>0.95  
Input Current - Full Load  
Inrush Current  
5.2/2.6  
30  
A
A
40  
250  
80  
Cold start 25 °C, 230 VAC  
Earth Leakage Current  
Patient Leakage Current  
Efficiency  
100/200  
55  
µA  
µA  
%
Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz  
89  
230 VAC, 250 W  
See derating curve, fig.8 and Thermal Considerations on  
page 8  
Operating Temperature  
EMC  
-40  
+70  
°C  
EN55032/11 Class B Conducted & Radiated, EN61000-3-2, EN61000-3-3  
EN62368-1, UL62368-1, CSA C22.2 No. 62368-1, IEC62368-1, IEC60950-1 Ed 2, IEC60601-1 Ed 3 Including Risk Management,  
ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:14  
Safety Approvals  
www.xppower.com  