175 Watts  
xppower.com  
CLC175 Series  
High Efficiency Resonant Topology  
High Power Density 9.3 W/in3  
12 V Fan Output as Standard  
Remote Sense as Standard  
5V Standby Option  
Remote On/Off Option  
Power Good Signal Option  
Specification  
Input  
General  
Input Voltage  
• 85-264 VAC (120-370 VDC), derate output  
power <90 VAC (See derating curve)  
Efficiency  
Isolation  
• 87ꢀ typical  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
Input Frequency  
Input Current  
• 47-63 Hz  
• 3.0 A typical at 115 VAC, full load  
1.5 A typical at 230 VAC, full load  
Switching Frequency  
Signals (Option -A)  
• 70 kHz typical  
Inrush Current  
• 40 A max at 230 VAC, cold start 25 ºC  
• EN61000-3-2, class A  
• Power OK - open collector,  
Remote On/Off, 5 V Standby  
Power Factor  
MTBF  
• 390 kHrs per MIL-HDBK-217F  
Earth Leakage Current • 200/400 µA 115/230 VAC at 50 Hz  
475 µA 264 VAC at 60 Hz  
Environmental  
Input Protection  
• Internal 5 A fuse  
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C  
at 2.5ꢀ/˚C to 50ꢀ load at +70 ˚C. See  
derating curve and longform datasheet for  
thermal information.  
Output  
Output Voltage  
• 12-48 V (see tables)  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
5ꢀ  
Cooling  
• Forced-cooled >10 CFM  
• 95ꢀ RH, non-condensing  
• -40 ˚C to +85 ˚C  
1ꢀ V1, 5ꢀ V2, 3ꢀ V3  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• 0.1A required for V2 regulation when used  
Start Up Delay  
• 1 s typical, see longform datasheet for  
more details  
• 3000 m  
• 30 g pk, half sine, 6 axis  
• 2 g rms, 5 Hz to 500 kHz, 3 axis  
Start Up Rise Time  
Hold Up Time  
Drift  
• 50 ms  
Vibration  
• 16 ms min at 115 VAC  
0.2ꢀ after 20 min warm up  
0.5ꢀ max  
EMC & Safety  
Line Regulation  
Load Regulation  
Over/Undershoot  
Transient Response  
Low Voltage PSU EMC • EN61204-3, high severity level as below  
1ꢀ V1, 5ꢀ V2 & V3 max  
Emissions  
• EN55022 level B conducted  
EN55022 level A radiated  
• 5ꢀ typical  
• 4ꢀ max. deviation, recovery to within  
1ꢀ in 500 µs for a 50-75-50ꢀ load  
change  
Harmonic Currents  
Voltage Flicker  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2, class A  
• EN61000-3-3  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
Ripple & Noise  
• 1ꢀ pk-pk V1, others 2ꢀ,  
20 MHz bandwidth  
Surge  
• EN61000-4-5, installation class 3  
Perf Criteria A  
Overvoltage Protection • 115-140ꢀ Vnom, recycle input to reset  
Overload Protection • 110-150ꢀ V1 only  
Short Circuit Protection • Continuous trip and restart (Hiccup mode)  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-6, level 3 Perf Criteria A  
• EN61000-4-11, 30ꢀ 10 ms,  
60ꢀ 100 ms, 100ꢀ 5000 ms  
Perf Criteria A, B, B  
Temperature  
Coefficient  
• 0.05ꢀ/˚C  
Remote Sense  
• Compensates for 0.5 V total voltage drop  
Safety Approvals  
• IEC60950-1 CB report, CSA 22.2 No.  
60950-1, UL60950-1, TUV EN60950-1  
Remote On/Off  
(Inhibit/Enable)  
(Option -A)  
• Uncommitted isolated optocoupler diode,  
powered diode inhibits V1 & V2