125 Watts  
xppower.com  
CLC Series  
125 W Forcedꢀcooled Rating  
Low Profile 1.25”  
Industry Standard 2x 4” & 3x 5” Package Sizes  
12 V Fan Supply  
Optional ORing Diode  
<0.5 W No Load Input Power  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage  
• 85-264 VAC (120-370 VDC),  
Derate output power linearly to 90% from  
90 VAC to 85 VAC  
• 47-63 Hz  
• 2.3 A typical at 115 VAC, full load  
1.1 A typical at 230 VAC, full load  
Efficiency  
Isolation  
• 88% typical  
• 3000 VAC Input to Output, 1500 VAC  
Input to Ground, 500 VDC Output to  
Ground  
• 65 KHz typical  
• 1,245 KHrs to Telecordia SR-332  
at 25 °C, GB  
Input Frequency  
Input Current  
Switching Frequency  
MTBF  
Inrush Current  
Power Factor  
• 40 A max at 230 VAC, cold start 25 °C  
• EN61000-3-2, class A  
Environmental  
No Load Input Power • <0.5 W  
Earth Leakage Current • 80/160 µA typical 115/230 VAC 50 Hz  
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C  
300 µA at 264 VAC/60 Hz max.  
at 2.5%/˚C to 50% load at +70 ˚C.  
Input Protection  
• Internal T5 A/250 V fuse in line  
Cooling  
• Forced cooled, 10 CFM  
• 95% RH, non-condensing  
Operating Humidity  
Storage Temperature • -40 ˚C to +85 ˚C  
Output  
Operating Altitude  
Shock  
• 3000 m  
• 30 g pk, half sine, 6 axes  
• 2 g rms, 5 Hz to 500 kHz, 3 axes  
Output Voltage  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
• 12-48 VDC (see tables)  
10%  
1%  
Vibration  
• No minimum load required  
• 1 s typical  
• 50 ms  
EMC & Safety  
Low Voltage PSU EMC • EN61204-3, high severity level as below  
Emissions  
• EN55022 level B conducted  
EN55022 level A radiated  
• 16 ms min at 230 VAC  
Drift  
0.2% after 20 min warm up  
0.5% max  
1%  
Harmonic Currents  
Voltage Flicker  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2, class A  
• EN61000-3-3  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
Line Regulation  
Load Regulation  
Over/Undershoot  
Transient Response  
• 5% typical  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 50-75-50% load  
change  
Surge  
• EN61000-4-5, installation class 3  
Perf Criteria A  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-6, level 3 Perf Criteria A  
• EN61000-4-11, 30% 10 ms, 60% 100 ms,  
100% 5000 ms, Perf Criteria A, B, B  
• IEC60950-1 CB report, CSA 22.2  
No. 60950-1, UL60950-1, TUV EN60950-1  
Ripple & Noise  
• 1% pk-pk V1, 20 MHz bandwidth  
Overvoltage Protection • 115-140% Vnom, recycle input to reset  
Overload Protection • 110-150%  
Short Circuit Protection • Continuous trip and restart (hiccup mode)  
Temperature  
Coefficient  
Safety Approvals  
• 0.05%/˚C  
Equipment Protection • Class I  
Class