xppower.com
XSxigxnxaxlxsxxxx
Remote On/Off (Inhibit/Enable)
1K
POWER SUPPLY
Figure 16
Enable (Hi)
5 V Standby
Pin 2, 4 & 6 CON 1
1K
Inhibit Hi
5 mA
Pin 10 CON 1
Inhibit Lo
Pin 9
CON 1
Logic GND
Pins 1, 3 & 5 CON 1
Signal Connector
1K
POWER SUPPLY
Figure 17
Enable (Lo)
5 V Standby
Pin 2, 4 & 6, CON 1
1K
Inhibit Hi
Pin 10
5 mA
CON 1
Inhibit Lo
Pin 9
CON 1
Logic GND
Pins 1, 3 & 5, CON 1
Signal Connector
Notes
1. At AC switch on the output (VI) may momentarily rise when the unit is disabled using the 5 V standby in conjunction with the Remote On/Off function.
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Derate linearly from +50 ºC at 2.5%/ºC
to 50% at 70 ºC. See fig.18 & Thermal
Considerations, p.11. (-40 ºC consult sales)
Operating Temperature
-20 (-40)
+70
ºC
Warm up Temperature
Storage Temperature
20
Minutes
ºC
-40
5
+85
Convection cooled.
See fig.18 & Thermal Considerations, p.12.
Cooling
Humidity
95
%RH
m
Non-condensing
Operating Altitude
3000
3 x 30 g/11 ms shocks in both +ve & -ve
directions along the 3 orthogonal axis,
total 18 shocks.
Shock
Vibration
Single axis 10-500 Hz at 2 g x 10 sweeps
8