CCM250PS12 参数 Datasheet PDF下载

CCM250PS12图片预览
型号: CCM250PS12
PDF下载: 下载PDF文件 查看货源
内容描述: [250 W Convection Cooled]
分类和应用:
文件页数/大小: 12 页 / 1675 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号CCM250PS12的Datasheet PDF文件第1页浏览型号CCM250PS12的Datasheet PDF文件第3页浏览型号CCM250PS12的Datasheet PDF文件第4页浏览型号CCM250PS12的Datasheet PDF文件第5页浏览型号CCM250PS12的Datasheet PDF文件第6页浏览型号CCM250PS12的Datasheet PDF文件第7页浏览型号CCM250PS12的Datasheet PDF文件第8页浏览型号CCM250PS12的Datasheet PDF文件第9页  
xppower.com  
Models and Ratings - Convection-cooled  
Output Power  
Output Current V1  
Output Voltage V1  
Standby Supply  
Model Number  
P nom  
250 W  
250 W  
250 W  
250 W  
250 W  
250 W  
P peak (1)  
300 W  
300 W  
300 W  
300 W  
300 W  
300 W  
I nom  
I peak (1)  
25 A  
12.0 VDC  
15.0 VDC  
24.0 VDC  
28.0 VDC  
36.0 VDC  
48.0 VDC  
20.8 A  
16.7 A  
10.4 A  
8.9 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
CCM250PS12  
CCM250PS15  
CCM250PS24  
CCM250PS28  
CCM250PS36  
CCM250PS48  
20 A  
12.5 A  
10.7 A  
8.3 A  
6.9 A  
5.2 A  
6.25 A  
Notes:  
1. Peak duration is 500 ms max, average power must not exceed 250 W.  
Input Characteristics  
Characteristic  
Minimum  
Typical  
115/230  
50/60  
Maximum  
275  
Units  
VAC  
Hz  
Notes & Conditions  
Derate output power <90 VAC. See fig 1.  
Power fail signal cannot be used <90 VAC.  
Input Voltage - Operating  
80  
47  
Input Frequency  
63  
>
Power Factor  
0.9  
EN61000-3-2 class A compliant  
115/230 VAC  
Input Current - No Load  
Input Current - Full Load  
Inrush Current  
0.13/0.17  
2.4/1.2  
A
A
115/230 VAC  
30  
A
230 VAC, 25 ºC  
Earth Leakage Current  
Input Protection  
90/160  
250  
µA  
115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)  
T5.0A/250 V internal fuse in both line and neutral  
Output Characteristics  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
Output Voltage - V1  
Initial Set Accuracy  
Output Voltage Adjustment  
Minimum Load  
Start Up Delay  
Hold Up Time  
12  
48  
See Models and Ratings table  
50% load, 115/230 VAC  
0.5(V1)  
,
5(V2)  
3
0
%
V1 only via potentiometer. See mech. details (page 11).  
A
0.5  
40  
s
230 VAC full load (see fig.2)  
90 VAC full load (see fig.3)  
After 20 min warm up  
90-264 VAC  
20  
ms  
%
Drift  
0.2  
0.5  
,
Line Regulation  
Load Regulation  
%
1(V1)  
5(V2)  
%
0-100% load.  
Recovery within 1% in less than 500 µs  
for a 50-75% and 75-50% load step  
Transient Response - V1  
4
5
%
Over/Undershoot - V1  
Ripple & Noise  
%
1(V1), 2(V2)  
% pk-pk  
%
20 MHz bandwidth (see fig.4 & 5)  
Overvoltage Protection  
Overload Protection  
115  
125  
140  
Vnom DC. Output 1 only, recycle input to reset  
Output 1 only, auto reset (see fig.6)  
165  
% I nom  
Short Circuit Protection  
Temperature Coefficient  
Overtemperature Protection  
Continuous, trip & restart (hiccup mode) all outputs  
0.05  
%/˚C  
°C  
110  
Auto recovery - temperature of main transformer  
2