200/250 Watts  
xppower.com  
CCB200/250 Series  
200 & 250 W Convection Cooled  
Very Low Heat Loss  
+70 °C Full Power Operation (CCB200)  
Very High Efficiency up to 95%  
5 V Standby, Inhibit & Power Fail Signals  
IT & Medical (BF) Safety Approvals  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• See derating curve  
• 47-63 Hz  
• 1.8/2.4 A typical at 115 VAC, full load  
(CCB200/250)  
0.9/1.2 A typical at 230 VAC, full load  
(CCB200/250)  
Efficiency  
Isolation  
• Up to 95%  
• 4000 VAC Input to Output 2 x MOPP,  
1500 VAC Input to Ground 1 x MOPP,  
1500 VAC Output to Ground 1 x MOPP  
• See longform datasheet  
• Power Fail  
Inhibit, 5 V Standby  
Switching Frequency  
Signals  
Inrush Current  
Power Factor  
• 30 A typical at 230VAC, cold start at 25 °C  
• >0.9  
MTBF  
• 369/230 kHrs to MIL-HDBK-217F at  
25 °C, GB (CCB250/200)  
Earth Leakage Current • 250 µA max at 264 VAC/60 Hz  
No Load Input Power • <0.5 W when inhibit used (CCB200)  
Patient Leakage Current • 100 µA max, 264 VAC 60 Hz  
Environmental  
Operating Temperature • See derating curve & longform datasheet  
Cooling  
Input Protection  
• Internal T5.0 A/250 V fuse in line  
and neutral  
• Convection cooled  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• 95% RH, non-condensing  
• -40 °C to +85 °C  
• 3048 m for CCB250, 5000 m for CCB200  
Output  
Output Voltage  
Output Voltage Trim  
• 12-48 VDC (see tables)  
3% CCB250, 5% CCB200  
(See Mechanical Details)  
3 x 30g shocks in each plane, total 18  
shocks. 30g = 11ms ( 0.5 ms), half sine,  
conforms to EN60068-2-27 & EN60068-2-47  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
0.5% V1, 5% V2  
Vibration  
• Single axis 10 - 500 Hz at 2g sweep and  
endurance at resonance in all 3 planes.  
Conforms to EN60068-2-6  
• No minimum load required  
• 1 s typical  
• 0.5 s typical  
EMC & Safety  
Low Voltage PSU EMC • EN61204-3, high severity level  
Emissions  
• 16/20 ms min at 90 VAC (CCB250/200)  
Drift  
0.2% after 20 min warm up  
0.5% max  
1% V1, 5% V2  
• EN55011/22 level B conducted  
EN55011/22 level A radiated,  
See longform datasheet for level A  
• EN61000-3-2, class A, >140w class C  
• EN61000-3-3  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, installation class 3  
Perf Criteria A  
• EN61000-4-6, level 3 Perf Criteria A  
• EN61000-4-11, 30% 10 ms, 60% 100 ms,  
100% 5000 ms, Perf Criteria A, B, B,  
EN60601-1-2, 30% 500 ms, 60% 100 ms,  
100% 10 ms, 100% 5000 ms, Perf Criteria  
A, A, A, B - 230 VAC. Consult longform  
datasheet for 115 V operation.  
• IEC60950-1 CB report, UL60950-1, TUV  
EN60950-1, IEC60601-1 CB report,  
UL60601-1, TUV 60601-1,  
Line Regulation  
Load Regulation  
Over/Undershoot  
Transient Response  
• 5% max  
Harmonic Currents  
Voltage Flicker  
Radiated Immunity  
EFT/Burst  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 50-75-50% load  
change  
Ripple & Noise  
• 1% pk-pk, 20 MHz bandwidth  
Surge  
Overvoltage Protection 115-140% Vnom, recycle input to reset (V1  
only)  
Conducted Immunity  
Dips & Interruptions  
Overload Protection  
• 125-165% Inom V1 (CCB250), 110 - 150%  
Inom V1 (CCB200)  
Short Circuit Protection • Continuous trip and restart (hiccup mode)  
Temperature  
Coefficient  
Remote On/Off  
(Inhibit/Enable)  
• 0.05%/°C  
• Uncommitted isolated optocoupler diode,  
powered diode inhibits V1  
Safety Approvals  
Equipment Protection • EN60601-1, ANSI/AAMI ES60601-1,  
Class  
CSA22.2 No.60601-1 per cUL BF Rated,  
Including Risk Management, EN60950,  
UL60950