欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCC400PS24 参数 Datasheet PDF下载

BCC400PS24图片预览
型号: BCC400PS24
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 84 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号BCC400PS24的Datasheet PDF文件第2页  
200-400 Watts  
BCC Series  
xppower.com  
Baseplate-cooled  
Wide Operating Temperature Range  
ETSI, EMC and Environmental Compliant  
Parallel Operation  
Active PFC  
Remote On/Off  
Low Temperature Option  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• 80% typꢀcal  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
• 3 A max at 90 VAC (BCC200)  
6 A max at 90 VAC (BCC400)  
Switching Frequency  
MTBF  
• PWM 360 kHz typ, PFC 90 kHz typ  
Inrush Current  
Power Factor  
• 60 A at 264 VAC +25 ºC cold start  
• >0.9  
• 160 kHrs per MIL-HDBK-217F at 25 ºC  
Earth Leakage Current • <1.5 mA at 230 VAC  
Environmental  
Input Protection  
• Internal 10 A fuse  
Operating Temperature • -20 ºC to +70 ºC, wꢀth baseplate  
maꢀntaꢀned below +83 ºC utꢀlꢀzꢀng system  
coolꢀng, -40 ºC optꢀon avaꢀlable - add  
Output  
Output Power  
• See table  
suffꢀx ‘L’ to model number  
Output Voltage  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Hold Up Time  
• See table  
Cooling  
• Conductꢀon vꢀa 6mm baseplate  
• 60% to 110% Vnom  
Operating Humidity  
• 20-95% RH, non-condensꢀng. Unꢀts can  
be conformally coated for hꢀgh humꢀdꢀty  
envꢀronments - add suffꢀx ‘E’  
1% nomꢀnal  
• No mꢀnꢀmum load  
• 10 ms mꢀn  
Storage Temperature  
Shock & Vibration  
• -40 ºC to +85 ºC  
• 2 g 10 mꢀn/1 cycle, 10 Hz to 500 kHz,  
60 mꢀns each axꢀs  
Line Regulation  
Load Regulation  
Ripple & Noise  
0.5%  
• See table  
• <1% pk-pk, 20 MHz bandwꢀdth  
EMC & Safety  
Overvoltage Protection • 105-140% Vnom  
(3.3 V versꢀon 130-166%)  
Emissions  
• EN55022, level B conducted &  
level A radꢀated  
Overtemperature  
Protection  
• Shuts down at +115 ºC baseplate  
temperature wꢀth auto recovery  
Harmonic Currents  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2, EN61000-3-3  
• EN61000-4-2, level 3 Perf Crꢀterꢀa A  
• EN61000-4-3, 3 V/m Perf Crꢀterꢀa A  
• EN61000-4-4, level 3 Perf Crꢀterꢀa A  
• EN61000-4-5, level 3 Perf Crꢀterꢀa A  
• EN61000-4-6, level 3 Perf Crꢀterꢀa A  
Overload Protection  
• 102-140% constant current lꢀmꢀtꢀng wꢀth  
auto recovery  
Temperature  
Coefficient  
• 0.05%/ºC  
Surge  
Remote Sense  
• Compensates for lead drops of up to  
500 mV  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-11, 30% 10 ms,  
60% 100 ms, 100% 5000 ms,  
Perf Crꢀterꢀa A, B, B  
Remote On/Off  
• A logꢀc ‘0’ on the Remote On/Off  
connectꢀon electronꢀcally dꢀsables  
the output  
Safety Approvals  
• UL60950-1:2003,  
Current Share  
• Up to 3 power supplꢀes can be connected  
ꢀn parallel sharꢀng wꢀthꢀn 10%, total output  
power derates by 10%  
CSA22.2 No. 60950-1-03, CE Mark LVD  
EN60950-1:2001