AC-DC Power Supplies
ASB110 Series
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Min.
Typ.
Max.
Units
VDC
%
Notes & Conditions
12
48
See Models and Ratings table
At 60% load
1
No minimum load required
1.3
20
s
ms
ms
%
10
Full load and 115 VAC
Line Regulation
Load Regulation
0.5
0.5
%
Maximum deviation, recovering to less
than 1% within 300 µs for 25% step load
Transient Response
Ripple and Noise
2
1
%
20 MHz bandwidth, measured with 20 MHz Bandwidth and
10 µF electrolytic in parallel with 0.1 µF ceramic capacitor.
% pk-pk
Overload Protection
Overvoltage Protection
Short Circuit Protection
Thermal Protection
130
110
210
140
%
%
Recycle mains to reset
Trip and restart (hiccup), auto resetting
Measured internally, auto resetting
0.02
Temperature Coefficient
%/°C
Environmental
Characteristic
Operating Temperature
Cooling
Minimum
Typical
Maximum
Units
Notes & Conditions
-40
+85
°C
Baseplate Temperature, see derating curve
Conduction Cooled via Baseplate
Operating Humidity
Storage Temperature
Operating Altitude
Shock
5
90
%RH
°C
Non-condensing
-40
+85
3048
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
Vibration
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
EMC: Emissions
Phenomenon
Emissions
Standard
EN55022
Test Level
Level B
Notes & Conditions
Harmonic Current
Voltage Flicker
EN61000-3-2
EN61000-3-3
Class A
EMC: Immunity
Phenomenon
Standard
EN61000-4-2
Test Level
Criteria
Notes & Conditions
ESD
3/2
3 V/m
3
A
A
8 kV air/ 4 kV contact
Radiated
EFT/Burst
Surge
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
A
Installation Class 3
3 V
A
Conducted
A
Dip: 100% 10 ms
Dip: 30% 500 ms
Int:100% 5000 ms
A
Dips and Interruptions
EN61000-4-11
A/B
B
High Line/Low Line
Safety Approvals
Safety Agency
Safety Standard
UL60950-1
Notes & Conditions
UL
TUV
CB
EN60950-1
IEC60950-1
www.xppower.com