AC-DC Power Supplies  
ASB110 Series  
Output  
Characteristic  
Output Voltage  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
Min.  
Typ.  
Max.  
Units  
VDC  
%
Notes & Conditions  
12  
48  
See Models and Ratings table  
At 60% load  
1
No minimum load required  
1.3  
20  
s
ms  
ms  
%
10  
Full load and 115 VAC  
Line Regulation  
Load Regulation  
0.5  
0.5  
%
Maximum deviation, recovering to less  
than 1% within 300 µs for 25% step load  
Transient Response  
Ripple and Noise  
2
1
%
20 MHz bandwidth, measured with 20 MHz Bandwidth and  
10 µF electrolytic in parallel with 0.1 µF ceramic capacitor.  
% pk-pk  
Overload Protection  
Overvoltage Protection  
Short Circuit Protection  
Thermal Protection  
130  
110  
210  
140  
%
%
Recycle mains to reset  
Trip and restart (hiccup), auto resetting  
Measured internally, auto resetting  
0.02  
Temperature Coefficient  
%/°C  
Environmental  
Characteristic  
Operating Temperature  
Cooling  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
-40  
+85  
°C  
Baseplate Temperature, see derating curve  
Conduction Cooled via Baseplate  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
5
90  
%RH  
°C  
Non-condensing  
-40  
+85  
3048  
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes  
Vibration  
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes  
EMC: Emissions  
Phenomenon  
Emissions  
Standard  
EN55022  
Test Level  
Level B  
Notes & Conditions  
Harmonic Current  
Voltage Flicker  
EN61000-3-2  
EN61000-3-3  
Class A  
EMC: Immunity  
Phenomenon  
Standard  
EN61000-4-2  
Test Level  
Criteria  
Notes & Conditions  
ESD  
3/2  
3 V/m  
3
A
A
8 kV air/ 4 kV contact  
Radiated  
EFT/Burst  
Surge  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
A
Installation Class 3  
3 V  
A
Conducted  
A
Dip: 100% 10 ms  
Dip: 30% 500 ms  
Int:100% 5000 ms  
A
Dips and Interruptions  
EN61000-4-11  
A/B  
B
High Line/Low Line  
Safety Approvals  
Safety Agency  
Safety Standard  
UL60950-1  
Notes & Conditions  
UL  
TUV  
CB  
EN60950-1  
IEC60950-1  
www.xppower.com  