120 Watts
xppower.com
AMM120 Series
•
•
•
•
•
•
•
Energy Star Level V ≥ 24 V
CEC 2008 & EISA 2007 Compliant
Worldwide Medical Approvals
Small Size/High Power Density
Class I and Class II Versions
Operating Temperature up to +60 °C
Locking Output Connector
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
Isolation
• 85% typical
• 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Switching Frequency
Power Density
MTBF
• 40-120 kHz variable
• 3.7 W/In3
Inrush Current
Power Factor
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
• 0.98 typical
• >175 kHrs per MIL-HDBK-217F
Earth Leakage Current • 90 µA max at 115 VAC/60 Hz,
Environmental
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 3 A fuse in live and neutral lines
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Output
Cooling
• Convection-cooled
Output Voltage
• 12 to 48 VDC
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 10-95% RH, non-condensing
• -20 °C to +80 °C
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• Not user-adjustable
•
2 %
• 3000 m
• No minimum load required
• 2 s max at 115 VAC
• 30 g, 10 ms on 3 axes
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
Start Up Delay
Vibration
Start Up Rise Time
Hold Up Time
• <80 ms at 115 VAC
EMC & Safety
• 15 ms minimum at full load & 115 VAC
• 0.5% maximum
Emissions
• EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
Line Regulation
Load Regulation
Transient Response
• Total regulation < 5%
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Surge
Overload Protection
• 110-150%, auto recovery
Conducted Immunity
Magnetic Field
Dips & Interruptions
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C
T
• EN61000-4-11, 70% U for 10 ms,
T
T
40% U for 100 ms, <5% U for 5000 ms
Perf Criteria A, B, B (Perf Criteria A, A, B
with 70% load)
Safety Approvals
• EN60601-1, UL60601-1, CSA22.2 No.
601-1 per cUL, CE Mark