120 Watts  
xppower.com  
AMM120 Series  
Energy Star Level V 24 V  
CEC 2008 & EISA 2007 Compliant  
Worldwide Medical Approvals  
Small Size/High Power Density  
Class I and Class II Versions  
Operating Temperature up to +60 °C  
Locking Output Connector  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• 85% typical  
• 4000 VAC Input to Output  
1500 VAC Input to Ground (Class I only)  
500 VAC Output to Ground (Class I only)  
• 1.6 A rms at 115 VAC,  
0.8 A rms at 230 VAC  
Switching Frequency  
Power Density  
MTBF  
• 40-120 kHz variable  
• 3.7 W/In3  
Inrush Current  
Power Factor  
• 60 A at 115 VAC, 120 A at 230 VAC,  
cold start +25 °C  
• 0.98 typical  
• >175 kHrs per MIL-HDBK-217F  
Earth Leakage Current • 90 µA max at 115 VAC/60 Hz,  
Environmental  
(Class I Versions)  
150 µA max at 230 VAC/50 Hz  
Input Protection  
• Internal 3 A fuse in live and neutral lines  
Operating Temperature • 0 °C to +60 °C, derate from 100% power  
at +40 °C to 50% power at +60 °C  
Output  
Cooling  
• Convection-cooled  
Output Voltage  
• 12 to 48 VDC  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• 10-95% RH, non-condensing  
• -20 °C to +80 °C  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
• Not user-adjustable  
2 %  
• 3000 m  
• No minimum load required  
• 2 s max at 115 VAC  
• 30 g, 10 ms on 3 axes  
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes  
Start Up Delay  
Vibration  
Start Up Rise Time  
Hold Up Time  
• <80 ms at 115 VAC  
EMC & Safety  
• 15 ms minimum at full load & 115 VAC  
• 0.5% maximum  
Emissions  
• EN55011/FCC/VCCI, Class B conducted  
EN55011/FCC/VCCI, Class B radiated  
Line Regulation  
Load Regulation  
Transient Response  
Total regulation < 5%  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 25% load change  
• EN61000-3-3  
• EN61000-4-2, level 3 Perf Criteria A  
• EN61000-4-3, level 2 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, level 3 Perf Criteria A  
• EN61000-4-6, 3 V Perf Criteria A  
• EN61000-4-8, 3 A/m Perf Criteria A  
Ripple & Noise  
• 2% max pk-pk (see note 1)  
Overvoltage Protection • 110-140% Vnom, recycle input to reset  
Overtemperature  
Protection  
• Unit shuts down, recycle input to reset  
Surge  
Overload Protection  
• 110-150%, auto recovery  
Conducted Immunity  
Magnetic Field  
Dips & Interruptions  
Short Circuit Protection Trip and restart (Hiccup mode)  
Temperature  
Coefficient  
• 0.04%/°C  
T
• EN61000-4-11, 70% U for 10 ms,  
T
T
40% U for 100 ms, <5% U for 5000 ms  
Perf Criteria A, B, B (Perf Criteria A, A, B  
with 70% load)  
Safety Approvals  
• EN60601-1, UL60601-1, CSA22.2 No.  
601-1 per cUL, CE Mark