欢迎访问ic37.com |
会员登录 免费注册
发布采购

AML150PS19 参数 Datasheet PDF下载

AML150PS19图片预览
型号: AML150PS19
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 161 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AML150PS19的Datasheet PDF文件第2页  
150 Watts  
xppower.com  
AML150 Series  
High Power Density  
Single Outputs from 12 V to 24 V  
Universal Input  
High Efficiency  
0 °C to +70 °C Operating Temperature  
Non-standard Connectors Available  
International Safety Approvals  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• 88% min  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
Output 0 V is electrically connected to  
Input Ground  
• 2.0 A rms at 115 VAC,  
1.0 A rms at 230 VAC  
Inrush Current  
Power Factor  
• 60 A at 115 VAC, 120 A at 230 VAC,  
cold start +25 °C  
Switching Frequency  
Power Density  
MTBF  
• 20-80 kHz variable  
• 5.1 W/In3  
• 0.95 typical  
• >100 kHrs per MIL-HDBK-217F  
(+25 °C ambient at full load)  
Earth Leakage Current • 150 µA max at 115 VAC,  
250 µA max at 230 VAC  
Input Protection  
• Internal 4 A fuse  
• <1 W  
Environmental  
Standby Power  
Consumption  
Operating Temperature • 0 °C to +70 °C, derate from 100% power  
at +40 °C to 60% power at +70 °C  
Output  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• 10-95% RH, non-condensing  
• -20 °C to +80 °C  
Output Voltage  
• See table  
• 3000 m  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
• Not user-adjustable  
• 30 g, 10 ms on 3 axes  
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes  
2%  
Vibration  
• No minimum load required  
• 5 s max at 100 VAC  
Start Up Delay  
EMC & Safety  
Hold Up Time  
• 3 ms minimum at 100 VAC  
Emissions  
• EN55022/FCC/VCCI, Class B conducted  
EN55022/FCC/VCCI, Class B radiated  
Line Regulation  
Load Regulation  
Transient Response  
0.5% maximum  
• See table  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 25% load change  
• EN61000-3-3  
• EN61000-4-2, level 2 Perf Criteria A  
• EN61000-4-3, level 2 Perf Criteria A  
• EN61000-4-4, level 2 Perf Criteria A  
• EN61000-4-5, level 3 Perf Criteria A  
• EN61000-4-6, level 2 Perf Criteria A  
Ripple & Noise  
• 2% max pk-pk (see note 1)  
Overvoltage Protection • 110-140% Vnom, recycle input to reset  
Overtemperature  
Protection  
• Unit shuts down, recycle input to reset  
Surge  
Conducted Immunity  
Dips & Interruptions  
Overload Protection  
• 110-150%, auto recovery  
• EN61000-4-11, 30% for 10 ms,  
60% 100 ms, 100% 5000 ms,  
Perf Criteria A, B, B  
Short Circuit Protection Trip and restart (Hiccup mode)  
Temperature  
Coefficient  
• 0.04%/°C  
Safety Approvals  
• EN60950, UL60950,  
CSA22.2 No. 60950 per cUL, CE Mark