150 Watts
xppower.com
AMD150 Series
•
•
•
•
•
•
•
Energy Star Level V
CEC2008 & EISA2007 Compliant
Universal Input
High Efficiency
0 °C to +70 °C Operating Temperature
Non-standard Connectors Available
International Safety Approvals
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
Efficiency
Isolation
• 88ꢀ min
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 2.0 A rms at 115 VAC,
1.0 A rms at 230 VAC
Inrush Current
Power Factor
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Switching Frequency
Power Density
MTBF
• 20-80 kHz variable
• 5.1 W/In3
• 0.95 typical
• >100 kHrs per MIL-HDBK-217F
(+25 °C ambient at full load)
Earth Leakage Current • 150 µA max at 115 VAC,
250 µA max at 230 VAC
No Load Input Power • <0.5 W
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100ꢀ power
Output
at +40 °C to 60ꢀ power at +70 °C
Output Voltage
• See table
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 10-95ꢀ RH, non-condensing
• -20 °C to +80 °C
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• Not user-adjustable
•
2ꢀ
• 3000 m
• No minimum load required
• 5 s max at 100 VAC
• 30 g, 10 ms on 3 axes
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
Start Up Delay
Vibration
Hold Up Time
• 3 ms minimum at 100 VAC
EMC & Safety
Line Regulation
Load Regulation
Transient Response
•
0.5ꢀ maximum
• See table
Emissions
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
• 4ꢀ max. deviation, recovery to within
1ꢀ in 500 µs for a 25ꢀ load change
Harmonic Currents
Voltage Flicker
ESD Immunity
• EN61000-3-2
• EN61000-3-3
Ripple & Noise
• 2ꢀ max pk-pk (see note 1)
Overvoltage Protection • 110-140ꢀ Vnom, recycle input to reset
• EN61000-4-2, 15 kv contact and
air discharge
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Radiated Immunity
EFT/Burst
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
Overload Protection
• 110-150ꢀ, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Surge
Temperature
Coefficient
• 0.04ꢀ/°C
Conducted Immunity
Dips & Interruptions
• EN61000-4-11, 30ꢀ for 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms,
Perf Criteria A, B, B
Safety Approvals
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark