欢迎访问ic37.com |
会员登录 免费注册
发布采购

ALM200 参数 Datasheet PDF下载

ALM200图片预览
型号: ALM200
PDF下载: 下载PDF文件 查看货源
内容描述: [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 684 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号ALM200的Datasheet PDF文件第1页浏览型号ALM200的Datasheet PDF文件第3页浏览型号ALM200的Datasheet PDF文件第4页  
AC-DC Power Supplies  
ALM200 Series  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
19, 24 & 48V models: Derate linearly from 100% load at 90  
VAC to 80% load at 80 VAC. 300 VAC/5 s maximum.  
12 & 15 V models: Derate linearly from 100% load at 100  
VAC to 95% load at 90 VAC and then derate linearly 80%  
load at 80 VAC, 300 VAC/5 s maximum.  
Input Voltage  
80  
47  
264  
VAC  
Input Frequency  
Input Current  
Inrush Current  
63  
Hz  
A
A
2.0/1.0  
>0.9  
Measured at 115/230 VAC  
230 VAC, cold start at 25 °C  
EN61000-3-2 Class A  
264 VAC, 60 Hz  
160  
Power Factor  
Earth Leakage Current  
No Load Input Power  
Input Protection  
250  
0.15  
µA  
W
T5A/250 VAC internal fuse in both line & neutral  
Output  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Output Voltage  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
12  
48  
2
VDC  
%
See Models and Ratings table  
At 50% load  
No minimum load required  
1
1.5  
40  
s
ms  
ms  
%
20  
30  
Full load and 115/230 VAC  
Line Regulation  
Load Regulation  
0.5  
%
See Models and Ratings table  
Maximum deviation, recovering to less than 1% within  
500 µs for 50-75-50% load change  
20 MHz bandwidth, measured with 20 MHz Bandwidth and  
10 µF electrolytic in parallel with 0.1 µF ceramic capacitor.  
At turn on / turn off  
Transient Response  
Ripple and Noise  
4
%
1.5  
% pk-pk  
Overshoot  
5
10  
175  
150  
%
%
%
Overload Protection  
Overvoltage Protection  
Short Circuit Protection  
Thermal Protection  
Temperature Coefficient  
Patient Leakage Current  
115  
Recycle mains to reset  
Trip and restart (hiccup), auto resetting  
Measured internally, auto resetting  
0.02  
%/°C  
µ A  
95  
264 VAC, 60 Hz  
Environmental  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Operating Temperature  
Cooling  
0
+60  
°C  
Derate from 100% load at 40 °C to 35% load at 60 °C  
Natural convection  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
5
-25  
95  
+80  
5000  
%RH  
°C  
m
Non-condensing  
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes  
Vibration  
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes  
Derating Curve  
100%  
80%  
60%  
40%  
20%  
0
60  
20  
40  
Ambient Temperature (ºC)  
www.xppower.com  