AC-DC Power Supplies  
ALM150 Series  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
Criteria  
Notes & Conditions  
ESD  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
3
A
A
A
A
A
A
A
A/B  
15 kV air/ 8 kV contact  
80-2700 MHz. IEC60601-1-2 Ed.4 at other frequencies  
Radiated  
EFT/Burst  
Surge  
Conducted  
Magnetic Fields  
10 V/m  
3
Installation Class 3  
10 V  
4
Dip: 30% 500 ms  
Dip: 60% 200 ms  
High Line/Low Line  
Dip: 20% 5000 ms  
Int: 100% 10 ms  
Int: 100% 20 ms  
A
A
A
B
A
A
A
A
B
EN61000-4-11  
EN60601-1-2  
Int: 100% 5000 ms  
Dips and Interruptions  
Dip: 30% 25 AC Cycles  
Dip: 60% 5 AC Cycles  
Int: 100% 0.5 AC Cycles  
Int: 100% 1.0 AC Cycles  
Int: 100% 250 AC Cycles  
230 VAC 100% load, 100 VAC 25% load  
Safety Approvals  
Safety Agency  
UL  
Safety Standard  
UL62368-1  
Notes & Conditions  
TUV  
CB  
CE  
EN62368-1  
IEC60950-1 & IEC62368-1  
LVD  
Information Technology  
UL  
ANSI/AAMI ES 60601-1/ANSI/AAMI HA60601-1-11  
CSA C22.2 No. 60601/CAN/CSA-C22.2 No.60601-1-11  
EN60601-1/EN60601-1-11  
CSA  
TUV  
CB  
Medical  
(60601-1-11 is for class II versions only)  
IEC60601-1/IEC60601-1-11  
Others  
CCC, PSE, KC & RCM  
May require additional importer information  
Mechanical Details  
0.193  
(4.9)  
7.32 (186.0)  
35.43 0.79 (900.0 20.0)  
1.41 0.079 (36.0 2.0)  
ø0.78 0.079 (ø20.0 2.0)  
4 Pin Power DIN  
(KPPX-4P Equivalent  
Non-locking type)  
2.83  
(72.0)  
Shell  
1.96 0.78 (50.0 20.0)  
AC Input  
IEC 320-C8  
1.49  
Pin  
1
Connection  
+Vout  
(38.0)  
2
+Vout  
0.039 (1.0)  
1.96 (50.0)  
3.94 (100.3)  
3
4
RTN  
RTN  
Standard Models:  
Functional Earth  
C2 Models: Floating  
AC Input  
IEC 320-C14  
1.58  
(40.3)  
Shell  
6.10 (155.0)  
Notes  
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except  
output cable length.  
2. Weight: 1.4 lbs (635 g) approx.  
3. For European mains lead order part EU-MAINS-IEC for C14 versions,  
or EU-MAINS-8 for C8 versions.  
4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8  
for C8 versions.  
5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8  
for C8 versions.  
6. Output connector: 4 pin power din with pin 1 & 2 - positive and pin  
3 & 4 - return, equivalent to KPPX-4P (non-locking).  
www.xppower.com  
21 Jan 19