AC-DC Power Supplies  
AKM36 Series  
36 Watt  
• Energy Efficiency Level VI  
xxx Series  
• European CoC Tier 2  
• Medical and ITE Approvals  
• Class II Construction  
• Optional White Versions  
• Output Voltages from 9 V to 36 V  
• 3 Years Warranty  
Dimensions:  
The AKM36 series of desktop adaptors comply with the latest energy efficiency level VI standards  
with high active mode efficiency and extremely low no load power consumption. Available with a  
standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and  
medical applications while maintaining industry leading performance.  
AKM:  
4.25 x 1.97 x 1.33” (108.0 x 50.0 x 33.8 mm)  
Models & Ratings  
Output Power  
Output Voltage  
Output Current  
Total Regulation(1)  
Efficiency(2)  
Model Number(3)  
9.0 V  
12.0 V  
15.0 V  
18.0 V  
24.0 V  
30.0 V  
36.0 V  
4.0 A  
3.0 A  
2.4 A  
2.0 A  
1.5 A  
1.2 A  
1.0 A  
5%  
5%  
5%  
5%  
5%  
5%  
5%  
88.9%  
89.3%  
88.4%  
89.5%  
89.4%  
89.9%  
89.2%  
AKM36US09C2  
AKM36US12C2  
AKM36US15C2  
AKM36US18C2  
AKM36US24C2  
AKM36US30C2  
AKM36US36C2  
36 W  
Notes  
1. Total regulation includes initial set accuracy, line and load regulation.  
2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC.  
3. For white case version add suffix ‘-W’ e.g. AKM36US12C2-W. MOQ applies,  
contact sales for details.  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
VAC  
Hz  
A
A
Notes & Conditions  
Input Voltage  
Input Frequency  
Input Current  
Inrush Current  
Power Factor  
90  
47  
264  
63  
1.0  
70  
90 VAC  
230 VAC, cold start at 25 °C  
EN61000-3-2, class A  
No Load Input Power  
Input Protection  
75  
mW  
Internal fuse in line  
Output  
Characteristic  
Output Voltage  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
Minimum  
Typical  
Maximum  
Units  
V
A
Notes & Conditions  
9
0
36  
See Models and Ratings table  
No minimum load required  
4
s
30  
ms  
ms  
%
10  
Full load and 100 VAC  
See Models and Ratings table  
Recovery within <1% within 500 µs for a 60% step load  
change at 0.15 A/µs  
Total Regulation  
5
4
Transient Response  
Ripple & Noise  
% deviation  
mV pk-pk  
Measured with 20 MHz bandwidth and 10 µF electrolytic in  
parallel with 0.1 µF ceramic capacitor  
200  
Short Circuit Protection  
Temperature Coefficient  
Continuous, trip and restart (hiccup mode) with auto recovery  
0.05  
%/˚C  
www.xppower.com  