xppower.com  
Models and Ratings - Convection-cooled  
Output Power  
85 W  
Output Voltage V1  
12.0 VDC  
Max Output Current  
7.08 A  
Peak(2)  
Model Number(1)  
AHM85PS12  
85 W  
15.0 VDC  
5.67 A  
AHM85PS15  
85 W  
19.0 VDC  
4.47 A  
AHM85PS19  
85 W  
24.0 VDC  
3.54 A  
AHM85PS24  
85 W  
85 W  
85 W  
85 W  
12.0 VDC  
15.0 VDC  
19.0 VDC  
24.0 VDC  
7.08 A  
5.67 A  
4.47 A  
3.54 A  
AHM85PS12C2  
AHM85PS15C2  
AHM85PS19C2  
AHM85PS24C2  
Notes:  
1. Models with suffix ‘C2’ have a Class II equipment protection classification.  
2. For optional input connector retention clip, add suffix ‘-A’ to the model number  
e.g. AHM85PS24C2-A.  
Input Characteristics  
Characteristic  
Minimum  
Typical  
115/230  
50/60  
Maximum  
264  
Units  
VAC  
Hz  
Notes & Conditions  
Full power 90 VAC to 264 VAC. Derate output power linearly by  
20% from 90 VAC to 80 VAC.  
Input Voltage - Operating  
80  
47  
Input Frequency  
63  
>
Power Factor  
0.9  
EN61000-3-2 class A & D compliant & Energy Star Compliant  
Input Current - No Load  
Input Current - Full Load  
Inrush Current  
0.05/0.09  
0.8/0.4  
60-80  
0.3/0.4  
50/85  
A
A
A
W
µA  
mA  
115/230 VAC  
115/230 VAC  
120  
0.5  
180  
230 VAC cold start, 25 ºC  
115/230 VAC  
115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.)  
115/230 VAC/400 Hz  
No Load Input Power  
Earth Leakage Current  
Input Protection  
0.3/0.6  
T2.5A/250 V internal fuse in both lines  
Output Characteristics  
Characteristic  
Output Voltage - V1  
Output Voltage Adjustment  
Minimum Load  
Start Up Delay  
Hold Up Time  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
12  
48  
See Models and Ratings table  
No user adjustment  
0
A
200/100  
15  
ms  
ms  
%
115/230 VAC full load (see fig.1)  
115/230 VAC full load (see fig.2)  
After 20 min warm up  
Drift  
0.2  
0.5  
3
Line Regulation  
Load Regulation  
%
90-264 VAC (50% load)  
0f50g100% load.  
%
Recovery within 1% in less than 500 µs for a 50-75% and 75-  
50% load step  
Transient Response - V1  
5
%
Over/Undershoot - V1  
Ripple & Noise  
3
%
% pk-pk  
%
<1  
1.5  
20 MHz bandwidth with external circuit (see fig.3-6)  
Vnom, Recycle AC to reset  
AHM85PS12 & C2  
125  
13.2  
16.5  
21.0  
26.4  
115.0  
8.5  
18  
22  
Overvoltage Protection  
Overload Protection  
AHM85PS15 & C2  
VDC  
%
28  
AHM85PS19 & C2  
33  
AHM85PS24 & C2  
175  
12.0  
9.6  
7.6  
6.0  
I nom, Auto reset  
AHM85PS12 & C2  
6.8  
AHM85PS15 & C2  
A
4.9  
AHM85PS19 & C2  
4.2  
AHM85PS24 & C2  
Short Circuit Protection  
Temperature Coefficient  
Overtemperature Protection  
Continuous, trip & restart (hiccup mode)  
0.05  
%/˚C  
°C  
Connected to transformer. Auto reset.  
2