DC-HVDC Converter
AG Series
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Operating Temperature (case)
Operating Temperature (case)
Storage Temperature
Humidity
-25
-55
-55
+75
+85
+105
95
°C
°C
Standard operating temp, all models
Extended operating temp, -T models
°C
%RH
Non-condensing
Cooling
Natural Convection
Safety Approvals
Safety Agency
UL and TUV
CE
Safety Standard
IEC/UL/CSA/EN 62368
Notes & Conditions
CE Directive, RoHs and LVD
Where applicable
Where applicable
RoHS
RoHS 2 and 3 Directive (2011/65/EU)
General
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Isolation: Input to Output
Leakage Current
500
100
350
V
< 500 VDC Bias on Output Return
nA
Switching Frequency
Construction
50
kHz
Solid vacuum encapsulation, UL 94 V-0 rated.
Mean Time Between Failure
1.862
MHrs
Bellcore TR-332, GB, +25°C
Block Diagram
Connections
1
2
3
4
5
(-) Input
(+) Input
HV Out
HV RTN
Control
Recommended Solder Profile
Preheat/Soak
Temp Tsmin
Temp Tsmax
120°C
180°C
time ts (tsmin to tsmax
77sec
)
Time Above Liquidu
s
Temp TL
217°C
time tL
44sec
Peak Temp TP
Peak time >230°C
237.5°C
16sec
tP
Time 38.5°C to Peak
Max Ramp Rates
TP
4min 18sec
+/-2.6°C/sec
www.xppower.com
2