欢迎访问ic37.com |
会员登录 免费注册
发布采购

AFM30US24 参数 Datasheet PDF下载

AFM30US24图片预览
型号: AFM30US24
PDF下载: 下载PDF文件 查看货源
内容描述: [Energy Efficiency Level V]
分类和应用:
文件页数/大小: 2 页 / 363 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AFM30US24的Datasheet PDF文件第2页  
30-60 Watts  
AFM Series  
xppower.com  
Energy Efficiency Level V  
CEC2008 & EISA2007 Compliant  
IT & Medical Approvals  
China Compulsory Certification (CCC) Qualified  
Optional Class II Versions  
Optional White Case Versions  
3 Year Warranty  
Specification  
Input  
General  
Efficiency  
Energy Efficiency  
• See table  
• Level V  
Input Voltage  
• 80-264 VAC, derate output power 25%  
<90 VAC  
Isolation  
• 4000 VAC Input to Output, 2 x MOPP  
1500 VAC Input to Ground, 1 x MOPP*  
Output 0 V is electrically connected to  
Input Ground*. *Not C8 version.  
Input Frequency  
Input Current  
• 47-63 Hz  
• AFM30: 0.8 A rms at 115VAC,  
AFM45: 1.2 A rms at 115VAC,  
AFM60: 1.5 A rms at 115 VAC  
• AFM30: 50 A max at 240VAC,  
AFM45: 50 A max at 240VAC,  
AFM60: 120 A max at 240VAC  
Switching Frequency  
Power Density  
• 30/45 W: 58 kHz typ., 60 W: 52 kHz typ.  
Inrush Current  
Power Factor  
3
3
• AFM30: 2.8 W/In , AFM45: 4.2 W/In ,  
3
AFM60: 3.76 W/In  
MTBF  
• >250 kHrs to MIL-HDBK-217F at 25 °C,  
GB, full load  
• EN61000-3-2, class A  
Earth Leakage Current • 150 µA max at 264 VAC/60 Hz  
No Load Input Power • AFM30/45: <0.3 W, AFM60: <0.5 W  
Environmental  
Operating Temperature • 0 °C to +60 °C, derate from 100% power  
at +40 °C to 60% power at +60 °C  
• 10-95% RH, non-condensing  
• -40 °C to +80 °C  
Output  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
Output Voltage  
• See table  
• Not user-adjustable  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
• 2000 m  
2%  
• 30 g, 10 ms on 3 axes  
• No minimum load required  
• 3 s max at 115 VAC  
2
Vibration  
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes  
Start Up Delay  
Hold Up Time  
• 8 ms minimum at 115 VAC  
EMC & Safety  
Emissions  
Line Regulation  
Load Regulation  
Transient Response  
1.0% maximum  
• EN55011/22/FCC Class B conducted,  
EN55011/22/FCC Class B radiated  
• EN61000-3-2, Class A  
• EN61000-3-3  
• EN61000-4-2, 6 kV contact and  
8 kV air discharge  
• 2.5% maximum  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 25% load change  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
(1)  
Ripple & Noise  
• 1% max pk-pk  
Overvoltage Protection 110-170% Vnom, recycle input to reset  
Overload Protection  
• AFM45/60: 110-170%,  
AFM30: 110-220%, auto recovery  
Radiated Immunity  
EFT/Burst  
• EN61000-4-3, 3 V/m Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, installation class 3  
Perf Criteria A  
• EN61000-4-6, 3 Vrms Perf Criteria A  
• EN61000-4-8, 3 A/m, Perf Criteria A  
(7)  
Short Circuit Protection Trip and restart (hiccup mode)  
Temperature  
Coefficient  
Surge  
• 0.04%/°C  
Conducted Immunity  
Magnetic Field  
Dips & Interruptions  
• EN61000-4-11, 30% for 10 ms,  
60% 100 ms, 100% 5000 ms,  
Perf Criteria A, B, B  
EN60601-1-2, 30% 500 ms, 60% 100 ms,  
100% 10 ms, 100% 5000 ms,  
(8)  
Perf A, A, A, B  
Safety Approvals  
• EN60950-1, UL60950-1, IEC60950-1  
EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.),  
IEC60601-1 (3rd Ed.) China Compulsory  
Certification (CCC) Qualified.