xppower.com
120 Watts
AFM Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC2008 & EISA2007 Compliant
IT & Medical Approvals
High Efficiency
0 °C to +70 °C Operating Temperature
Optional IEC320ꢀC6 Inlet
3 Year Warranty
Specification
Input
General
Input Voltage
• 80-264 VAC, derate output power 25%
Efficiency
• >87%
<90 VAC
• 47-63 Hz
• 2.0 A rms at 115 VAC,
1.0 A rms at 230 VAC
• 40 A at 115 VAC, 60 A at 230 VAC,
cold start +25 °C
Energy Efficiency
Isolation
• Level V
Input Frequency
Input Current
• 4000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 65 kHz - 100 kHz variable
• 4.5 W/In
Inrush Current
Power Factor
Switching Frequency
Power Density
MTBF
3
• >0.9
Earth Leakage Current • 250 µA max at 264 VAC
No Load Input Power • <0.5 W
• >100 kHrs per MIL-HDBK-217F at 25 °C,
GB
Environmental
Output
Operating Temperature • 0 °C to +60 °C, derate from 100% power
Output Voltage
• See table
• Not user-adjustable
at +40 °C to 60% power at +60 °C
• 10-95% RH, non-condensing
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Operating Humidity
•
2%
Storage Temperature • -40 °C to +80 °C
Operating Altitude
Shock
• No minimum load required
• 3 s max at 115 VAC
• 8 ms minimum at 115 VAC
• 3000 m
Start Up Delay
• 30 g, 10 ms on 3 axes
2
Hold Up Time
Vibration
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes
Line Regulation
Load Regulation
Transient Response
•
1.0% maximum
• See table
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
EMC & Safety
Emissions
• EN55011/22/FCC/Class B conducted
EN55011/22/FCC/Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, 4 kV contact and
8 kV air discharge
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Ripple & Noise
• 1% max pk-pk (see note 1)
Harmonic Currents
Voltage Flicker
ESD Immunity
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Overload Protection
• 110-150%, recycle input to reset
Radiated Immunity
EFT/Burst
Short Circuit Protection • Output shuts down, recycle input to reset
Temperature
Coefficient
• 0.04%/°C
Surge
• EN61000-4-5, installation Class 3
Perf Criteria A
Conducted Immunity
Magnetic Field
• EN61000-4-6, 3 Vrms Perf Criteria A
• EN61000-4-8, 3 A/m, Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf A, A, A, B
Safety Approvals
• EN60950-1, UL60950-1, IEC60950-1
EN60601-1, UL60601-1, IEC60601-1