内容描述: [Energy Efficiency Level V]
分类和应用:
文件页数/大小: 2 页 / 106 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AFM120PS12的Datasheet PDF文件第2页  
xppower.com  
120 Watts  
AFM Series  
Energy Efficiency Level V  
CEC2008 & EISA2007 Compliant  
IT & Medical Approvals  
High Efficiency  
0 °C to +70 °C Operating Temperature  
Optional IEC320ꢀC6 Inlet  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage  
• 80-264 VAC, derate output power 25%  
Efficiency  
• >87%  
<90 VAC  
• 47-63 Hz  
• 2.0 A rms at 115 VAC,  
1.0 A rms at 230 VAC  
• 40 A at 115 VAC, 60 A at 230 VAC,  
cold start +25 °C  
Energy Efficiency  
Isolation  
• Level V  
Input Frequency  
Input Current  
• 4000 VAC Input to Output  
1500 VAC Input to Ground  
Output 0 V is electrically connected to  
Input Ground  
• 65 kHz - 100 kHz variable  
• 4.5 W/In  
Inrush Current  
Power Factor  
Switching Frequency  
Power Density  
MTBF  
3
• >0.9  
Earth Leakage Current • 250 µA max at 264 VAC  
No Load Input Power • <0.5 W  
• >100 kHrs per MIL-HDBK-217F at 25 °C,  
GB  
Environmental  
Output  
Operating Temperature • 0 °C to +60 °C, derate from 100% power  
Output Voltage  
• See table  
• Not user-adjustable  
at +40 °C to 60% power at +60 °C  
• 10-95% RH, non-condensing  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Operating Humidity  
2%  
Storage Temperature • -40 °C to +80 °C  
Operating Altitude  
Shock  
• No minimum load required  
• 3 s max at 115 VAC  
• 8 ms minimum at 115 VAC  
• 3000 m  
Start Up Delay  
• 30 g, 10 ms on 3 axes  
2
Hold Up Time  
Vibration  
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes  
Line Regulation  
Load Regulation  
Transient Response  
1.0% maximum  
• See table  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 25% load change  
EMC & Safety  
Emissions  
• EN55011/22/FCC/Class B conducted  
EN55011/22/FCC/Class B radiated  
• EN61000-3-2, Class A  
• EN61000-3-3  
• EN61000-4-2, 4 kV contact and  
8 kV air discharge  
• EN61000-4-3, 3 V/m Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
Ripple & Noise  
• 1% max pk-pk (see note 1)  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Overvoltage Protection • 110-140% Vnom, recycle input to reset  
Overtemperature  
Protection  
• Unit shuts down, recycle input to reset  
Overload Protection  
• 110-150%, recycle input to reset  
Radiated Immunity  
EFT/Burst  
Short Circuit Protection • Output shuts down, recycle input to reset  
Temperature  
Coefficient  
• 0.04%/°C  
Surge  
• EN61000-4-5, installation Class 3  
Perf Criteria A  
Conducted Immunity  
Magnetic Field  
• EN61000-4-6, 3 Vrms Perf Criteria A  
• EN61000-4-8, 3 A/m, Perf Criteria A  
Dips & Interruptions  
• EN61000-4-11, 30% 10 ms,  
60% 100 ms, 100% 5000 ms,  
Perf Criteria A, B, B  
EN60601-1-2, 30% 500 ms, 60% 100 ms,  
100% 10 ms, 100% 5000 ms,  
Perf A, A, A, B  
Safety Approvals  
• EN60950-1, UL60950-1, IEC60950-1  