AC-DC Power Supplies
AEJ50 Series
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
Efficiency
89
See Models and Ratings table and curves.
3000
1500
VAC
VAC
Isolation: Input to Output
Input to Ground
Output to Ground
Negative output is connected to ground
Switching Frequency
Power Density
65
kHz
3
4.23
W/in
Mean Time Between Failure
Weight
285
kHrs
lb (g)
MIL-HDBK-217F at 25 °C GB for 24 V version
0.60 (300)
Efficiency Curves
AEJ50US12
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
AEJ50US24
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Standard
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Notes & Conditions
Emissions
Harmonic Current
Voltage Flicker
Level B
Class A
Conducted & Radiated
www.xppower.com
3