欢迎访问ic37.com |
会员登录 免费注册
发布采购

AEH80US12 参数 Datasheet PDF下载

AEH80US12图片预览
型号: AEH80US12
PDF下载: 下载PDF文件 查看货源
内容描述: AC- DC电源 [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 377 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号AEH80US12的Datasheet PDF文件第2页浏览型号AEH80US12的Datasheet PDF文件第3页浏览型号AEH80US12的Datasheet PDF文件第4页  
45-130 Watts  
AEH Series  
xppower.com  
Output Voltages from 2.5 V to 48 V  
Non-standard Outputs Available  
Universal Input  
Single & Multiple Output Versions  
0 °C to +70 °C Operating Temperature  
Efficiency up to 80%  
Non-standard Connectors Available  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• Up to 80%  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
• 1.5/0.7 A for AEH45, at 115/230 VAC  
1.9/1.5 A for AEH80, at 115/230 VAC  
3.2/1.7 A for AEH130, at 115/230 VAC  
Switching Frequency  
• 67-83 kHz for AEH45  
58 kHz typical for AEH80  
53-76 kHz for AEH130  
Inrush Current  
Power Factor  
• AEH45 & 80: 30 A max at 230 VAC  
AEH130: 60 A max at 230 VAC  
cold start  
MTBF  
• 100 kHrs per MIL-HDBK-217F  
• EN61000-3-2 class A  
Environmental  
Earth Leakage Current • <0.5 mA max at 115 VAC/60 Hz  
<0.75 mA max at 230 VAC/50 Hz  
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%  
load at +40 °C to 50% load at +70 °C  
Output  
Operating Humidity  
Storage Temperature  
Vibration  
• 5-95% RH, non-condensing  
• -40 °C to +85 °C  
Output Voltage  
• See tables. Factory set non-standard  
voltages available - contact sales  
• 2 g on 3 axes  
Initial Set Accuracy  
Start Up Delay  
• 5%  
EMC & Safety  
• 2 s max  
Hold Up Time  
• 16 ms min (>50 ms AEH130)  
• See note 2  
Emissions  
• EN55022 level B, conducted and radiated  
EN61000-3-2, Class A  
Line Regulation  
Load Regulation  
Transient Response  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• See note 2  
EN61000-3-2  
• 4% max deviation, recovery to within  
1% in 4 ms for a 50% load change  
• EN61000-4-2, level 2 Perf Criteria A  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 2 Perf Criteria A  
• EN61000-4-5, level 3 Perf Criteria A  
• EN61000-4-6, level 2 Perf Criteria A  
Ripple & Noise  
• 2% pk-pk for outputs 3.3 V  
1% pk-pk for all other outputs  
20 MHz BW  
Surge  
Conducted Immunity  
Dips & Interruptions  
Overvoltage Protection • 112-132% Vnom, auto reset  
• EN61000-4-11 30% 10 ms,  
60% 100 ms, 100% 5000 ms  
Perf Criteria A, B, B  
Overload Protection  
• Output 1 only 110-150% of nominal  
• 0.04%/°C max  
Temperature  
Coefficient  
Safety Approvals  
• EN60950-1, UL60950-1,  
CSA C22.2 No. 950 per cUL, CE Mark