15-24 Watts
AEH Series
xppower.com
•
•
•
•
•
•
•
Output Voltages from 3- 48 VDC Available
Non-Standard Outputs
Universal Input
+70 ºC Operating Temperature
High Efficiency - Up to 85%
Class 1 Earthing
Non-standard Connectors Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
Efficiency
Isolation
• Up to 85%
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 0.4 A for AEH15, at 230 VAC
0.7 A for AEH24, at 230 VAC
MTBF
• 100 kHrs per MIL-HDBK-217F
Inrush Current
• 15/30 A max at 115/230 VAC 100% load,
cold start
Environmental
Earth Leakage Current • <0.5 mA max at 115 VAC/60Hz
<0.75 mA max at 230 VAC/50Hz
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from
full load at +40 ˚C to half load at +70 ˚C
Output
Operating Humidity
Storage Temperature
Vibration
• 5-95 % RH, non-condensing
• -40 ˚C to +85 ˚C
Output Voltage
• See tables (factory set). Non-standard
voltages available - contact sales
• 2 g on 3 axes
Initial Set Accuracy
Start Up Delay
• 5%
EMC & Safety
• 2 s max
Hold Up Time
• 20 ms min at full load and 115 VAC
• See tables
Emissions
• EN55022 level B, conducted and radiated
• EN61000-3-2, Class A
Line Regulation
Load Regulation
Transient Response
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• See tables
• EN61000-3-3
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
Ripple & Noise
• 2% pk-pk, 20 MHz BW
Overvoltage Protection • 112-132% Vnom, auto reset
Surge
Overload Protection
• 112-132% of nominal, auto recovery
• 0.04% /˚C max
Conducted Immunity
Dips & Interruptions
Temperature
Coefficient
• EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
Safety Approvals
• EN60950, UL60950,
CSA C22.2 No. 950 per cUL,
UL60950