AEB36-100
ModelsandRatings
AEB36
Output Power
Output Voltage
Output Current
Load Regulation(1)
Efficiency(3)
Model Number
20 W
27 W
30 W
32 W
36 W
36 W
36 W
36 W
5.0 V
9.0 V
4.00 A
3.00 A
2.50 A
2.40 A
2.40 A
2.00 A
1.50 A
0.75 A
6%
5%
5%
5%
3%
2%
2%
2%
73%
77%
78%
80%
80%
81%
81%
83%
AEB36US05
AEB36US09
AEB36US12
AEB36US13
AEB36US15
AEB36US18
AEB36US24
AEB36US48
12.0 V
13.5 V
15.0 V
18.0 V
24.0 V
48.0 V
Notes
1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load).
2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
3. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
AEB45
Output Power
Output Voltage
Output Current
Load Regulation(1)
Efficiency(4)
Model Number(3)
45 W
45 W
45 W
45 W
45 W
48 W
12.0 V
15.0 V
18.0 V
19.0 V
24.0 V
48.0 V
3.75 A
3.00 A
2.50 A
2.37 A
1.88 A
1.00 A
3%
3%
2%
2%
2%
2%
84%
85%
85%
85%
86%
87%
AEB45US12
AEB45US15
AEB45US18
AEB45US19
AEB45US24
AEB45US48
Notes
1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load).
2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number.
4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
AEB70
Output Power
Output Voltage
Output Current
Load Regulation(1)
Efficiency(5)
Model Number(3)
66 W
69 W
70 W
72 W
72 W
72 W
12.0 V
15.0 V
18.0 V
19.0 V
24.0 V
48.0 V
5.50 A
4.60 A
3.90 A
3.70 A
3.00 A
1.50 A
5%
3%
2%
2%
2%
2%
82%
84%
84%
84%
85%
87%
AEB70US12
(4)
AEB70US15
(4)
AEB70US18
(4)
AEB70US19
(4)
AEB70US24
AEB70US48
(4)
Notes
1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load).
2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number.
4. Energy efficiency level V.
5. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
AEB100
Output Power
Output Voltage
Output Current
Load Regulation(1)
Efficiency(4)
Model Number(3)
100 W
100 W
100 W
100 W
100 W
12.0 V
12.5 V
15.0 V
24.0 V
48.0 V
8.34 A
8.00 A
6.67 A
4.17 A
2.08 A
4%
4%
4%
2%
2%
85%
85%
85%
85%
85%
AEB100PS12
AEB100PS125
AEB100PS15
AEB100PS24
AEB100PS48
Notes
1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% 40% full load).
2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number.
4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.