欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACM18US15 参数 Datasheet PDF下载

ACM18US15图片预览
型号: ACM18US15
PDF下载: 下载PDF文件 查看货源
内容描述: [AC-DC Power Supplies]
分类和应用:
文件页数/大小: 4 页 / 605 K
品牌: XPPOWER [ XP POWER LIMITED ]
 浏览型号ACM18US15的Datasheet PDF文件第1页浏览型号ACM18US15的Datasheet PDF文件第3页浏览型号ACM18US15的Datasheet PDF文件第4页  
AC-DC Power Supplies  
ACM18 Series  
General  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Typical average of efficiencies measured at 25%, 50%, 75%  
and 100% load and 115 VAC input  
Efficiency  
87  
%
Energy Efficiency  
Isolation  
Level VI  
4000  
VAC  
µA  
Input to Output  
Leakage Current  
Switching Frequency  
Mean Time Between Failure  
Weight  
30  
100  
70  
At 264 VAC, 60 Hz, from output to ground  
Variable  
24  
kHz  
kHrs  
lb (g)  
250  
MIL-HDBK-217F at 25 °C GB  
Body only  
0.18 (80)  
Environmental  
Characteristic  
Operating Temperature  
Storage Temperature  
Operating Humidity  
Operating Altitude  
Cooling  
Minimum  
Typical  
Maximum  
+60  
Units  
Notes & Conditions  
0
-20  
5
°C  
°C  
%
m
Derate from 100% load at 40 °C to 50% load at 60 °C  
+85  
90  
RH, non-condensing  
5000  
Natural convection  
Shock  
1 m drop onto concrete on each of 6 axes, non operating  
2 g, 0.3 decades/min, 15 mins for each of 3 axes  
Vibration  
10  
300  
Hz  
EMC: Emissions  
Phenomenon  
Conducted  
Standard  
Test Level  
Notes & Conditions  
EN55022  
EN55022  
Level B  
Level B  
Class A  
Radiated  
Harmonic Current  
Voltage Flicker  
EN61000-3-2  
EN61000-3-3  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
Criteria  
as below  
Notes & Conditions  
Medical Device EMC  
Low Voltage PSU EMC  
ESD Immunity  
IEC60601-1-2  
EN61204-3  
Ed.4.0 : 2014  
High severity level  
8 kV contact, 15 kV air  
10 V/m  
as below  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
A
A
A
A
A
A
A
B
B
A
A
A
B
Radiated Immunity  
EFT/Burst  
Level 3  
Surge  
Level 3  
Conducted Immunity  
Magnetic Fields  
6 V  
30 A/m  
Dip: 100% 10 ms  
Dip: 70% 500 ms  
Int: 100% 5000 ms  
Dip: 30% 25 AC Cycles  
Int: 100% 0.5 AC Cycle  
Int: 100% 1 AC Cycle  
Int.: >95% 5000 ms  
High Line/Low Line  
At 8 angles  
EN61000-4-11  
Dips and Interruptions  
EN60601-1-2  
Safety Approvals  
Safety Agency  
Safety Standard  
UL60950-1  
Notes & Conditions  
UL  
TUV  
CB  
EN60950-1  
Information Technology  
Medical  
IEC60950-1  
CE  
LVD  
UL  
ANSI/AAMI ES 60601-1  
CSA C22.2 No. 60601  
EN60601-1  
CSA  
TUV  
CB  
IEC60601-1  
www.xppower.com  
2