AC-DC Power Supplies
ACM06 Series
6 Watt
• Energy Efficiency Level VI
xxx Series
• European CoC Tier 2
• Medical and ITE Approvals
• Interchangeable Mains Connectors
• Optional White Versions
• Output Voltages from 5 V to 12 V
• Class II Construction
• 3 Years Warranty
Dimensions:
The ACM06 series of wall plug adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector as well as USB versions, these adaptors suit a wide variety of cost
sensitive industrial and medical applications while maintaining industry leading performance.
ACM (body only):
2.89 x 1.21 x 1.67” (73.5 x 30.7 x 42.5 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation(3)
Efficiency(4)
Model Number(1,2,5)
ACM06US05(6)
ACM06US09
5.0 V
9.0 V
1000 mA
600 mA
500 mA
5%
5%
5%
82.5%
86.7%
87.5%
6 W
12.0 V
ACM06US12
Notes
1. Model number is for body only. AC input plugs must be ordered separately, see
AC input plug section.
2. Other output voltages available, contact sales for details.
3. Total regulation includes initial set accuracy, line and load regulation.
4. Typical average value measured at 115 VAC.
5. For white case version add suffix ‘-W’ e.g. ACM06US12-W. MOQ applies, contact
sales for details.
6. For 5 V version with optional USB type A connector in case, add suffix -BB,
e.g ACM06US05-BB.
Input
Characteristic
Minimum
Typical
Maximum
Units
VAC
Hz
A
A
Notes & Conditions
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
90
47
264
63
0.2
70
100 VAC
240 VAC, cold start at 25 °C
EN61000-3-2, class A
No Load Input Power
Input Protection
75
mW
Internal fuse in both line and neutral
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Minimum
Typical
Maximum
Units
V
A
Notes & Conditions
5
0
12
See Models and Ratings table
No minimum load required
4
s
30
ms
ms
%
10
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Total Regulation
5
4
Transient Response
Ripple & Noise
% deviation
mV pk-pk
Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
150
Short Circuit Protection
Temperature Coefficient
Continuous, trip and restart (hiccup mode) with auto recovery
0.05
%/˚C
www.xppower.com
1