X24012
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature Under Bias.................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicatedintheoperationalsectionsofthisspecificationis
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Respect to V
............................... –1.0V to +7V
SS
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
70°C
+85°C
+125°C
X24012
4.5V to 5.5V
3V to 5.5V
–40°C
–55°C
X24012-3
X24012-2.7
2.7V to 5.5V
3847 PGM T02
3847 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
SCL=V x0.1/V x0.9Levels@
l
PowerSupplyCurrent(Read)
1
mA
CC1
CC
CC
100KHz, SDA=Open, AllOther
Inputs=GNDor V –0.3V
l
PowerSupplyCurrent(Write)
Standby Current
2
CC2
CC
(1)
(2)
I
I
50
µA
µA
SCL = SDA = V – 0.3V, All Other
CC
SB
Inputs = GND or V , V = 5.5V
CC
CC
Standby Current
30
SCL = SDA = V – 0.3V, All Other
CC
SB
Inputs = GND or V
V
= 3V
CC, CC
I
Input Leakage Current
Output Leakage Current
Input Low Voltage
10
10
µA
µA
V
V
V
= GND to V
CC
LI
IN
I
= GND to V
CC
LO
OUT
(2)
V
V
V
–1.0
V
x 0.3
lL
CC
CC
(2)
Input High Voltage
V
x 0.7
V
+ 0.5
V
IH
CC
Output Low Voltage
0.4
V
I
OL
= 3 mA
OL
3847 PGM T04
CAPACITANCE T = 25°C, F = 1.0MHZ, V = 5V
A
CC
Symbol
Test
Input/Output Capacitance (SDA)
Input Capacitance (A , A , A , SCL, WC)
Max.
Units
Conditions
(3)
C
C
8
6
pF
pF
V = 0V
I/O
I/O
(3)
V = 0V
IN
IN
0
1
2
3847 PGM T06
Notes: (1) Must perform a stop command prior to measurement.
(2) V min. and V max. are for reference only and are not tested.
IL IH
(3) This parameter is periodically sampled and not 100% tested.
9