欢迎访问ic37.com |
会员登录 免费注册
发布采购

X1243S8IT1 参数 Datasheet PDF下载

X1243S8IT1图片预览
型号: X1243S8IT1
PDF下载: 下载PDF文件 查看货源
内容描述: [Real Time Clock, 0 Timer(s), CMOS, PDSO8, PLASTIC, SOIC-8]
分类和应用: 时钟光电二极管外围集成电路
文件页数/大小: 18 页 / 285 K
品牌: XICOR [ XICOR INC. ]
 浏览型号X1243S8IT1的Datasheet PDF文件第1页浏览型号X1243S8IT1的Datasheet PDF文件第2页浏览型号X1243S8IT1的Datasheet PDF文件第4页浏览型号X1243S8IT1的Datasheet PDF文件第5页浏览型号X1243S8IT1的Datasheet PDF文件第6页浏览型号X1243S8IT1的Datasheet PDF文件第7页浏览型号X1243S8IT1的Datasheet PDF文件第8页浏览型号X1243S8IT1的Datasheet PDF文件第9页  
X1243 – Preliminary Information  
the clock on the ACK bit prior to RTC data output) into  
a separate latch to avoid time changes during the read  
operation. The clock continues to run. Alarms occurring  
during a read are unaffected by the read operation.  
read or page write operation provides access to the  
contents of only one section of the CCR per operation.  
Access to another section requires a new operation.  
Continued reads or writes, once reaching the end of a  
section, will wrap around to the start of the section. A  
read or page write can begin at any address in the CCR.  
Writing to the Real Time Clock  
The time and date may be set by writing to the RTC  
registers. To avoid changing the current time by an  
uncompleted write operation, the current time value is  
loaded into a separate buffer at the falling edge of the  
clock on the ACK bit before the RTC data input bytes,  
the clock continues to run. The new serial input data  
replaces the values in the buffer. This new RTC value  
is loaded back into the RTC Register by a stop bit at  
the end of a valid write sequence. An invalid write  
operation aborts the time update procedure and the  
contents of the buffer are discarded. After a valid write  
operation the RTC will reflect the newly loaded data  
beginning with the first “one second” clock cycle after  
the stop bit. The RTC continues to update the time  
while an RTC register write is in progress and the RTC  
continues to run during any nonvolatile write sequences.  
A single byte may be written to the RTC without affect-  
ing the other bytes.  
Section 5) is a volatile register. It is not necessary to set  
the RWEL bit prior to writing the status register. Section 5)  
supports a single byte read or write only. Continued reads  
or writes from this section terminates the operation.  
The state of the CCR can be read by performing a ran-  
dom read at any address in the CCR at any time. This  
returns the contents of that register location. Additional  
registers are read by performing a sequential read.The  
read instruction latches all Clock registers into a buffer,  
so an update of the clock does not change the time  
being read. A sequential read of the CCR will not result  
in the output of data from the memory array. At the end  
of a read, the master supplies a stop condition to end  
the operation and free the bus. After a read of the  
CCR, the address remains at the previous address +1  
so the user can execute a current address read of the  
CCR and continue reading the next Register.  
ALARM REGISTERS  
CLOCK/CONTROL REGISTERS (CCR)  
There are two alarm registers whose contents mimic  
the contents of the RTC register, but add enable bits  
and exclude the 24-hour time selection bit. The enable  
bits specify which registers to use in the comparison  
between the Alarm and Real Time Registers. For  
example:  
The Control/Clock Registers are located in an area log-  
ically separated from the array and are only accessible  
following a slave byte of “1101111x” and reads or  
writes to addresses [0000h:003Fh].  
CCR Access  
The contents of the CCR can be modified by performing  
a byte or a page write operation directly to any address in  
the CCR. Prior to writing to the CCR (except the status  
register), however, the WEL and RWEL bits must be  
set using a two step process (See section “Writing to  
the Clock/Control Registers.)  
– The user can set the X1242 to alarm every Wednes-  
day at 8:00AM by setting the EDWn, the EHRn and  
EMNn enable bits to ‘0’ and setting the DWAn, HRAn  
and MNAn Alarm registers to 8:00AM Wednesday.  
– A daily alarm for 9:30PM results when the EHRn and  
EMNn enable bits are set to ‘0’ and the HRAn and  
MNAn registers set 9:30PM.  
The CCR is divided into 5 sections.These are:  
– Setting the EMOn bit in combination with other  
enable bits and a specific alarm time, the user can  
establish an alarm that triggers at the same time  
once a year.  
1. Alarm 0 (8 bytes)  
2. Alarm 1 (8 bytes)  
3. Control (2 bytes)  
4. Real Time Clock (8 bytes)  
5. Status (1 byte)  
When there is a match, an alarm flag is set. The occur-  
rence of an alarm can be determined by polling the  
AL0 and AL1 bits, or by setting the AL0E and AL1E bits  
to ‘1’ and monitoring the IRQ output. The AL0E and  
AL1E bits enable the circuit that triggers the output  
IRQ pin when an alarm occurs. Writing a ‘0’ to one of  
Sections 1) through 3) are nonvolatile and Sections 4)  
and 5) are volatile. Each register is read and written  
through buffers. The nonvolatile portion (or the counter  
portion of the RTC) is updated only if RWEL is set and  
only after a valid write operation and stop bit. A sequential  
Characteristics subject to change without notice. 3 of 18  
REV 1.1.4 5/31/01  
www.xicor.com