A Dimensions: [mm]
B Surface Resistance vs. Compression:
D Electrical Properties:
Properties
Shielding effectiveness @ 100 MHz
Shielding effectiveness @ 1 GHz
Surface Resistance
Reference
based on MIL-STD-225
based on MIL-STD-225
Value
80
86
0.08
Unit
dB
dB
Ω
E General information:
•Storage Temperature: -25°C to 85°C
•Operating Temperature: -25°C to 85°C
•non-inflammable/ self extinguishing
•Test conditions of Electrical Properties: 25°C, 33% RH
if not specified differently
DESCRIPTION
Material
Metallized Fiber
Polyether Urethane Foam
Rayon Paper with acrylic Adhesive/
Aluminium foil with conductive adhesive
Reactive Polyurethane Hotmelt Adhesive
Flammability classification
WE-LT Conductive Shielding Gasket
UL94 HF-1
UL94 VTM-0/
none
4.1
4.0
3.0
REV
2013-04-24
2013-01-17
2011-08-22
DATE
SSt
SSt
WJ
BY
CHECKED
SSt
WJ
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
Order.- No.
SIZE
A4
3030602
Size: D-Profile
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.