WPMIx9200501S / 1779205x4  
MagI3C Power Module  
FISM Fixed Isolated SIP Module  
INTENDET USE Typical Application  
“Reinforced Isolation“  
“Functional Isolation“  
Primary Circuit  
Secondary Circuit (SELV Circuit)  
The 1779205x4 MagI3C Power Modules are only intended to be used as a CLASS III equipment according to the UL60950-1  
standard. That requires that the Power Module is supplied by a SELV (safe extra low voltage) circuit which provides  
protection against electric shock. There are no HAZARDOUS voltages present in CLASS III Equipment.  
A SELV circuit is a secondary circuit that is designed to be protected from excessive voltages (≥42 Vac or ≥ 60Vdc) during  
normal operating conditions and single fault conditions. A reinforced isolation is required at the boundary between the  
primary and the secondary circuit.  
A circuit which has no direct connection to the primary circuit and derives its power from a transformer, converter or  
equivalently isolated device, or a battery, is defined as a secondary circuit.  
In accordance to the Safety Standard UL60950-1, functional isolation (insulation) is defined as:  
“1.2.9.1 Functional Insulation: insulation that is necessary only for the correct functioning of the equipment  
NOTE: Functional Insulation by definition does not protect against electric shock. It may, however, reduce the likelihood of  
ignition and fire.”  
“1.2.9.5 Reinforced Insulation: single insulation system that provides a degree of protection against electric shock equivalent  
to Double Insulation under the conditions specified in this standard.  
NOTE: The Term “insulation system” does not imply that the insulation has to be in one homogeneous piece. It may  
comprise several layers that cannot be tested that cannot be tested as Basic Insulation and Supplementary Insulation  
The above Figure shows a typical application of an isolated Power Module. VDC1 is a hazardous voltage and  
VDC2 is a SELV voltage.  
ISOLATION VOLTAGE  
To verify the integrity of an isolation a test voltage is applied for a specified time across a component that is designed to  
provide electrical isolation. This test is known as a ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’,  
‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’.  
All isolated Power Modules are all 100% production tested at their stated isolation voltage. This is 4kVDC for 1 second.  
The isolation test voltage indicated in this datasheet is for voltage transient immunity only. It does not allow this part to be  
used within a safety isolation system.  
The part will function properly with several hundreds of volts applied continuously across the isolation barrier, however  
surrounding components must be individually analyzed to ensure proper insulation. Isolation measures are taken to prevent  
any user-accessible circuitry from causing harm.  
we-online.com  
©July 2016  
Würth Elektronik eiSos GmbH & Co. KG Data Sheet Rev. 1.0  