The Communications Edge TM
SCG002
InGaP HBT Gain Block
Product Information
Typical Device RF Performance
Supply Bias = +5 V, Rbias = 24 Ω, Icc = 45 mA
Frequency
S21
MHz
dB
100
22
500
21.6
-17
900
21
1900
20.5
-15
2140
19.7
-15
2400
19.2
-15
3500
17.4
-16
5800
14.3
-19
S11
dB
-18
-16
-18
S22
dB
-16.7
-17
-20
-21
-22
-35
-16
Output P1dB
Output IP3
Noise Figure
dBm
dBm
dB
+15.4 +15.6 +15.5
+15
+29
3.8
+15
+29
3.8
+15
+29
3.9
+14.5
+11
+28
3.9
+28
3.8
+29
3.8
1. Test conditions: T = 25 ºC, Supply Voltage = +5 V, Device Voltage = +3.9 V, Rbias = 24 Ω, Icc = 45 mA typical, 50 Ω System.
2. 3OIP measured with two tones at an output power of -1 dBm/tone separated by 1 MHz. The suppression on the largest IM3 product is used to calculate the 3OIP using a 2:1 rule.
3. Data is shown as device performance only. Actual implementation for the desired frequency band will be determined by external components shown in the application circuit.
Gain vs. Frequency
S11, S22 vs. Frequency
Vdevs. Icc
120
100
80
60
40
20
0
22
20
18
16
14
12
0
-5
-10
-15
-20
-25
-30
-35
-40
S11
+25C
S22
+25C -40C +85C
0
1
2
3
4
5
6
0.0
1.0
2.0
Vde (V)
3.0
4.0
5.0
500
1000
1500
2000
2500
3000
Frequency (MHz)
Frequency (GHz)
OIP3 vs. Frequency
Noise Figure vs. Frequency
P1dB vs. Frequency
32
30
28
26
24
4.5
20
4
3.5
3
18
16
14
12
10
2.5
+25C -40C +85C
+25C -40C +85C
2
500
1000
1500
2000
500
1000
1500
2000
2500
3000
500
1000
1500
2000
2500
3000
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
Typical Device S-Parameters
S-Parameters (Vdevice = +3.9 V, ICC = 45 mA, T = 25 °C, calibrated to device leads)
Freq (MHz)
50
S11 (dB)
-33.66
-25.70
-22.88
-20.95
-21.62
-22.23
-21.00
-20.58
-22.29
-24.96
-38.73
-27.75
-22.85
S11 (ang)
160.38
57.47
73.66
88.39
77.79
25.60
16.65
10.75
4.19
19.24
11.58
-158.73
-167.85
S21 (dB)
22.12
21.92
21.40
20.67
19.85
19.15
18.29
17.55
16.72
15.98
15.29
14.67
14.12
S21 (ang)
177.97
160.79
142.72
126.57
111.46
99.29
86.85
74.67
62.69
51.73
S12 (dB)
-23.51
-23.66
-23.41
-23.49
-23.03
-23.10
-22.58
-22.06
-21.59
-20.86
-20.66
-19.86
-19.66
S12 (ang)
-0.74
0.45
0.69
1.82
2.10
1.10
2.16
0.98
-1.56
-5.93
-8.63
-10.67
-12.11
S22 (dB)
S22 (ang)
-42.92
-25.55
-22.04
-16.66
-14.30
-15.12
-13.92
-12.97
-11.90
-10.64
-9.87
-10.61
-59.74
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
-132.34
-164.52
-178.04
-177.70
170.72
153.21
137.74
126.68
121.15
119.72
122.34
41.78
32.60
23.12
-10.03
-10.68
Device S-parameters are available for download off of the website at: http://www.wj.com
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: sales@wj.com • Web site: www.wj.com
Page 2 of 4 April 2006