AG303-86
InGaP HBT Gain Block
Product Information
AG303-86G (Green / Lead-free Sot-86 Package) Mechanical Information
This package is lead-free/Green/RoHS-compliant. It is compatible with both lead-free (maximum 260°C reflow temperature) and leaded
(maximum 245°C reflow temperature) soldering processes. The plating material on the pins is annealed matte tin over copper.
Outline Drawing
Product Marking
The component will be marked with an “P”
designator followed by a two-digit numeric
lot code on the top surface of the package.
Tape and reel specifications for this part are
located on the website in the “Application
Notes” section.
MSL / ESD Rating
ESD Rating: Class 1C
Value:
Test:
Passes at 1000 V min.
Human Body Model (HBM)
JEDEC Standard JESD22-A114
Standard:
ESD Rating: Class IV
Value:
Test:
Passes at 1000 V min.
Charged Device Model (CDM)
JEDEC Standard JESD22-C101
Standard:
Land Pattern
MSL Rating: Level 3 at +260° C convection reflow
Standard: JEDEC Standard J-STD-020
Mounting Config. Notes
1. Ground / thermal vias are critical for the proper performance
of this device. Vias should use a .35mm (#80 / .0135”)
diameter drill and have a final plated thru diameter of .25 mm
(.010”).
2. Add as much copper as possible to inner and outer layers near
the part to ensure optimal thermal performance.
3. Mounting screws can be added near the part to fasten the
board to a heatsink. Ensure that the ground / thermal via
region contacts the heatsink.
4. Do not put solder mask on the backside of the PC board in the
region where the board contacts the heatsink.
5. RF trace width depends upon the PC board material and
construction.
6. Use 1 oz. Copper minimum.
7. All dimensions are in millimeters (inches). Angles are in
degrees.
Thermal Specifications
MTTF vs. GND Lead Temperature
10000
1000
100
10
Parameter
Rating
-40 to +85 °C
335 °C/W
135 °C
Operating Case Temperature
Thermal Resistance, Rth (1)
Junction Temperature, Tjc (2)
1. The thermal resistance is referenced from the hottest part
of the junction to the ground lead (pin 2 or 4).
1
2. This corresponds to the typical biasing condition of
60
70
80
90
100
110
120
+4.23V, 35 mA at an 85 °C case temperature.
A
Ground Lead Temperature (°C)
minimum MTTF of 1 million hours is achieved for
junction temperatures below 177 °C.
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: sales@wj.com • Web site: www.wj.com Page 6 of 6 June 2005