LM2931-5.0
Input Voltage
Operating Range
Overvoltage Protection
PJ2931
26V
50V
Internal Power Dissipation(Note 1)
Operating Temperature Range
Maximum Junction Temperature
Storage Temperature Range
Lead Temp.(Soldering, 10 seconds)
Internally Limited
0
70
125
to
+150
210
(V
=14V,Io=10mA, T
=25(Note 1), C2=100F(unless otherwise specified)
''
(
LM
LM
!"#$%&
5
)
V
V
V
V
mV
mV
mV
m!
mA
mA
mA
mA
Output Voltage
6.0V V
26V,
Io 100mA
-40 Tj 125
9V V
16V
6V V
26V
5mA 100mA
100mA
and 10mArms,
100Hz-10KHz
26V
-40 Tj 125
Io=100mA,V
=14V,Tj=25
10Hz-100KHz, C
=100F
5
5.19
4.81
5.25
4.75
5.25
4.75
5.5
4.5
Line Regulation
Load Regulation
Output Impedance
Quiescent Current
2
4
14
200
0.4
15
500
20
10
30
50
600
1.0
1.0
30
5
1000
50
2
4
14
200
0.4
15
500
20
10
30
50
1.0
1.0
Output Noise
Voltage
Long Term
Stability
Ripple Rejection
Dropout Voltage
fo=120Hz
Io=10mA
Io=100mA
80
,
55
0.2
0.6
80
,
Maximum
Operational Input
26
Voltage
Maximum Line
R
=500 5.5V,100ms
70
60
Transient
Reverse Polarity
-30
-15
Vo -0.3V, R
=500!
Input Voltage,DC
Reverse Polarity
=500!
Input Voltage,
-80
-50
Transient
Note 1:To ensure constant junction temperature, low duty cycle pulse testing is used.
Note 2:Guaranteed and 100% production tested.
0.3
33
0.3
33
0.2
0.6
26
mV
/1000hr
dB
V
V
V
V
V
70
-30
50
-15
V
-80
-50
V
Note 3:Guaranteed (but not 100% production tested)over the operating temperature and input current ranges. These limits are
not used to calculate outgoing quality levels.
Note 4:Thermal resistance junction-to-case (jc) is 3/W; case-to-ambient is 50/W.
2-6