欢迎访问ic37.com |
会员登录 免费注册
发布采购

CCP-18N23C-T 参数 Datasheet PDF下载

CCP-18N23C-T图片预览
型号: CCP-18N23C-T
PDF下载: 下载PDF文件 查看货源
内容描述: [Commercial Normally Open Multi-throw, DC-3GHz, Low PIM]
分类和应用:
文件页数/大小: 10 页 / 591 K
品牌: TELEDYNE [ TELEDYNE TECHNOLOGIES INCORPORATED ]
 浏览型号CCP-18N23C-T的Datasheet PDF文件第2页浏览型号CCP-18N23C-T的Datasheet PDF文件第3页浏览型号CCP-18N23C-T的Datasheet PDF文件第4页浏览型号CCP-18N23C-T的Datasheet PDF文件第5页浏览型号CCP-18N23C-T的Datasheet PDF文件第6页浏览型号CCP-18N23C-T的Datasheet PDF文件第7页浏览型号CCP-18N23C-T的Datasheet PDF文件第8页浏览型号CCP-18N23C-T的Datasheet PDF文件第10页  
Series CCP-18N  
Low PIM Multi-Throw DC–3 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
GLOSSARY  
Actuator  
TD-Option  
An actuator is the electromechanical mechanism that This option includes a decoder. The 3-bit parallel command  
transfers the RF contacts from one position to another upon is decoded to internally select the appropriate position. See  
DC command.  
the logic tables. The TD-Option increases the Vsw supply  
current demand by 50mA max at 28Vdc and +20°C.  
Arc Suppression Diode  
A diode is connected in parallel with the coil. This diode Performance Parameters vs Frequency  
limits the “reverse EMF spike” generated when the coil de- Generally speaking, the RF performance of coaxial switches  
energizes to 0.7 volts. The diode cathode is connected to is frequency dependent. With increasing frequency, VSWR  
the positive side of the coil and the anode is connected to and insertion loss increase while isolation decreases. All  
the negative side.  
data sheets specify these three parameters as “worst case”  
at the highest operating frequency. If the switch is to be  
used over a narrow frequency band, better performance  
Date Code  
All switches are marked with either a unique serial number can be achieved.  
or a date code. Date codes are in accordance with MIL-  
STD-1285 Paragraph 5.2.5 and consist of four digits. Actuator Current vs Temperature  
The rst two digits dene the year and the last two digits The resistance of the actuator coil varies as a function of  
dene the week of the year (YYWW). Thus, 1032 identies temperature. There is an inverse relationship between the  
switches that passed through nal inspection during the operating temperature of the switch and the actuator drive  
32nd week of 2010.  
current. For switches operating at 28 VDC, the approximate  
actuator drive current at temperature, T, can be calculated  
using the equation:  
Indicator  
Indicators tell the system which position the switch is in.  
Other names for indicators are telemetry contacts or tellback  
circuit. Indicators are usually a set of internally mounted DC  
contacts linked to the actuator. They can be wired to digital  
input lines, status lights, or interlocks. Unless otherwise  
specied, the maximum indicator contact rating is 30 Vdc,  
50 mA, or 1.5 Watts into a resistive load.  
I
A
I
=
T
[1 + .00385 (T-20)]  
Where:  
I
I
=
=
Actuator current at temperature, T  
T
Room temperature actuator current –  
see data sheet  
A
Isolation  
Isolation is the measure of the power level at the output  
connector of an unconnected RF channel as referenced to  
the power at the input connector. It is specied in dB below  
the input power level.  
T
=
Temperature of interest in °C  
Magnetic Sensitivity  
Multi-Throw Switch  
An electro-mechanical switch can be sensitive to ferrous  
A multi-throw switch is a switch with one input and three or materials and external magnetic elds. Neighboring ferrous  
more output ports. The CCS-18 can switch a microwave materials should be permitted no closer than 0.5 inches and  
signal to any of 2,3,4,5 or 6 output from a single common adjacent external magnetic elds should be limited to a ux  
input.  
density of less than 5 Gauss.  
Switching Time  
Switching time is the total interval beginning with the arrival  
of the leading edge of the command pulse at the switch DC  
input and ending with the completion of the switch transfer,  
including contact bounce. It consists of three parts: (1)  
inductive delay in the coil, (2) transfer time of the physical  
movement of the contacts, and (3) the bounce time of the  
RF contacts.  
TTL Switch Driver Option  
As a special option, switch drivers can be provided for both  
failsafe and latching switches, which are compatible with  
industry-standard low-power Schottky TTL circuits.  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCP-18 Page 9  
CCP-18\072013\Q3