V23990-P768-A50-PM
flow2
1200V/50A
Output Inverter Application
Figure 5
Phase
Figure 6
Phase
Typical available 50Hz output current
as a function Mi*cosφ
Typical available 50Hz output current
as a function of switching frequency
Iout = f(Mi*cos φ)
Iout = f(fsw)
80
70
60
50
40
30
20
10
0
80
Th = 60°C
70
Th = 60°C
60
Th = 100°C
Th = 100°C
50
40
30
20
10
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
1
10
100
Mi*cos φ
fsw (kHz)
At
At
Tj =
Tj =
150
°C
V
kHz
150
°C
V
DC link = 600
fsw
DC link = 600
Mi*cos φ = 0,8
Th from
=
4
Th from
60 °C to 100 °C in steps of 5 °C
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
out = f(fsw, Mi*cos φ)
Figure 8
Typical available 0Hz output current as a function
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
I
Ioutpeak = f(fsw)
of switching frequency
80
-1,00
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
70
60
50
Th = 60°C
65,0-75,0
55,0-65,0
Iout (A)
Th = 100°C
40
45,0-55,0
35,0-45,0
25,0-35,0
15,0-25,0
30
20
10
0
1
10
100
1
2
4
8
16
32
64
fsw (kHz)
fsw
At
Tj =
At
Tj =
150
°C
150
DC link = 600
°C
V
DC link = 600
Th =
V
°C
Th from
80
60 °C to 100 °C in steps of 5 °C
Mi =
0
copyright Vincotech
2
Revision: 1