10-FZ06NIA050SA-P925F33
preliminary datasheet
flowNPC0
600V/50A
NPC Application
Figure 9.
for Buck IGBT+FWD
Figure 10.
for Buck IGBT+FWD
Typical available output current as a function of
phase displacement φ
Typical available output current as a function of
switching frequency fsw
Iout=f(φ)
Iout=f(fsw)
70
70
Th=50°C
Th=50°C
60
60
50
40
30
20
10
50
Th=100°C
40
Th=100°C
30
20
10
0
0
1
0
15
30
45
60
75
90
105
120
135
150
165
180
10
100
φ
fsw (kHz)
Conditions:
parameter:
Tj= Tjmax-25 °C
fsw=
20 kHz
Conditions:
Tj= Tjmax-25 °C
φ= 0 °
DC link=
700
V
DC link=
700
V
Heatsink temp.
parameter: Heatsink temp.
Th from
in
50
10
°C to
°C
100
°C
Th from
in
50
10
°C to
°C
100
°C
steps
steps
Figure 11.
for Buck IGBT+FWD
Typical available 50Hz output current as a function of
fsw and phase displacement φ
Iout=f(fsw,φ)
180
165
150
135
120
105
90
φ
Iout (A)
55-60
45-50
35-40
25-30
15-20
5-10
50-55
40-45
30-35
20-25
10-15
0-5
75
60
45
30
15
0
2
4
8
16
32
64
128
fsw (kHz)
Conditions:
Tj= Tjmax-25 °C
DC link=
Th=
700
80
V
°C
copyright by Vincotech
3
Revision: 1