PRELIMINARY
Specifications, continued
SAFETY SPECIFICATIONS
Parameter
Isolation voltage
Input to output
Isolation resistance
Agency approvals (pending)
Min
2,250
10
cTÜVus
CE Mark
Typ
Max
Unit
Vdc
MΩ
Input to output
UL/CSA 60950, EN 60950
Low voltage directive
Notes
Complies with basic insulation requirements
THERMAL SPECIFICATIONS
Parameter
Operating case temperature
Storage temperature
Temperature limiting
Thermal capacity
Pin soldering temperature
Wave
Hand
Min
-40
-40
125
130
22.8
500 (260)
750 (390)
Typ
Max
100
+150
135
Unit
°C
°C
°C
Ws/°C
°F (°C)
°F (°C)
<5 sec
<7 sec
Junction temperature, PRM or VTM
Notes
Measured at output side of VTM
GENERAL SPECIFICATIONS
Parameter
MTBF
MIL-HDBK-217F
Weight
Dimensions
Min
Typ
1,500
3.7 (104)
2.28 x 1.45 x 0.27
57,9 x 36,8 x 6,8
Max
Unit
khrs
oz (g)
in
mm
LxWxH
LxWxH
Notes
25°C, GB
CONTROL SPECIFICATIONS – ON/OFF PIN
Parameter
Disable voltage (P version)
Enable voltage (P version)
Enable voltage (M version)
Disable voltage (M version)
Min
– 0.6
2.8
– 0.6
1.8
Typ
Max
1.7
6.2
0.7
6.2
Unit
Vdc
Vdc
Vdc
Vdc
Notes
Referenced to –in
Referenced to –in
Referenced to –in
Referenced to –in
Vicor Corporation
Tel: 800-735-6200
vicorpower.com
VICBrick DC-DC Converter
Rev. 1.5
Page 6 of 14