欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BD1E13A2C06 参数 Datasheet PDF下载

BCM4414BD1E13A2C06图片预览
型号: BCM4414BD1E13A2C06
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 42 页 / 1364 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第22页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第23页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第24页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第25页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第27页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第28页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第29页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第30页  
BCM4414xD1E13A2yzz  
Where:  
PMBus™ Interface  
Refer to “PMBus Power System Management Protocol Specification  
Revision 1.2, Part I and II” for complete PMBus specifications details  
visit http://pmbus.org.  
X, is a “real world” value in units (A, V, °C, s)  
Y, is a two’s complement integer received from the BCM controller  
m, b and R are two’s complement integers defined as follows:  
Device Address  
Command  
TON_DELAY  
Code  
60h  
88h  
89h  
8Bh  
8Ch  
8Dh  
96h  
A0h  
A1h  
A4h  
A5h  
A6h  
A7h  
D1h  
D4h  
m
R
3
1
3
1
2
0
0
0
0
0
0
0
0
0
5
b
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
The PMBus address (ADDR Pin) should be set to one of a  
predetermined 16 possible addresses shown in the table below  
using a resistor between ADDR pin and SGND pin.  
1
READ_VIN  
1
READ_IIN  
1
The BCM accepts only a fixed and persistent address and does not  
support SMBus address resolution protocol. At initial power up, the  
BCM controller will sample the address pin voltage, and will keep  
this address until device power is removed.  
READ_VOUT [1]  
READ_IOUT  
1
1
READ_TEMPERATURE_1 [2]  
READ_POUT  
1
Slave  
Address  
Recommended  
Resistor RADDR (Ω)  
ID  
HEX  
1
MFR_VIN_MIN  
MFR_VIN_MAX  
MFR_VOUT_MIN  
MFR_VOUT_MAX  
MFR_IOUT_MAX  
MFR_POUT_MAX  
READ_K_FACTOR  
READ_BCM_ROUT  
1
1
2
1010 000b  
1010 001b  
1010 010b  
1010 011b  
1010 100b  
1010 101b  
1010 110b  
1010 111b  
1011 000b  
1011 001b  
1011 010b  
1011 011b  
1011 100b  
1011 101b  
1011 110b  
1011 111b  
50h  
51h  
52h  
53h  
54h  
55h  
56h  
57h  
58h  
59h  
5Ah  
5Bh  
5Ch  
5Dh  
5Eh  
5Fh  
487  
1050  
1
1
3
1870  
1
4
2800  
1
5
3920  
1
65536  
1
6
5230  
7
6810  
8
8870  
9
11300  
14700  
19100  
25500  
35700  
53600  
97600  
316000  
[1] Default READ LO side voltage returned when BCM unit is disabled = –300V.  
[2] Default READ Temperature returned when BCM unit is disabled = –273°C.  
10  
11  
12  
13  
14  
15  
16  
No special formatting is required when lowering the supervisory  
limits and warnings.  
Reported DATA Formats  
The BCM controller employs a direct data format where all  
reported measurements are in Volts, Amperes, Degrees Celsius,  
or Seconds. The host uses the following PMBus specification  
to interpret received values metric prefixes. Note that the  
COEFFICIENTS command is not supported:  
1
m
X =  
(
• (Y • 10-R - b)  
)
BCM® in a VIA Package  
Page 26 of 42  
Rev 1.5  
10/2016  
vicorpower.com  
800 927.9474  
 复制成功!