 浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第6页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第7页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第8页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第9页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第11页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第12页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第13页浏览型号BCM4414BD1E13A2C06的Datasheet PDF文件第14页  
BCM4414xD1E13A2yzz  
PMBus™ Reported Characteristics  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of -40°C TCASE  
100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Monitored Telemetry  
ACCURACY  
(RATED RANGE)  
FUNCTIONAL  
REPORTING RANGE  
UPDATE  
RATE  
ATTRIBUTE  
PMBusTM READ COMMAND  
REPORTED UNITS  
HI Side Voltage  
HI Side Current  
LO Side Voltage[1]  
LO Side Current  
LO Side Resistance  
Temperature[2]  
(88h) READ_VIN  
(89h) READ_IIN  
5%(LL - HL)  
130V to 450V  
-0.85A to 5.9A  
4.25V to 14V  
100µs  
100µs  
100µs  
100µs  
100ms  
100ms  
VACTUAL = VREPORTED x 10-1  
IACTUAL = IREPORTED x 10-3  
VACTUAL = VREPORTED x 10-1  
IACTUAL = IREPORTED x 10-2  
RACTUAL = RREPORTED x 10-5  
TACTUAL = TREPORTED  
20%(10 - 20% of FL)  
5%(20 - 133% of FL)  
(8Bh) READ_VOUT  
5%(LL - HL)  
20%(10 - 20% of FL)  
5%(20 - 133% of FL)  
(8Ch) READ_IOUT  
-27A to 190A  
5%(50 - 100% of FL) at NL  
10%(50 - 100% of FL)(LL - HL)  
(D4h) READ_ROUT  
1.0mΩ to 3.0mΩ  
- 55ºC to 130ºC  
(8Dh) READ_TEMPERATURE_1  
7°C(Full Range)  
[1] Default READ LO Side Voltage returned when unit is disabled = -300V.  
[2] Default READ Temperature returned when unit is disabled = -273°C.  
Variable Parameters  
• Factory setting of all Thresholds and Warning limits listed below are 100% of specified protection values.  
• Variables can be written only when module is disabled with VHI < VHI_UVLO- and external bias (VDDB) applied.  
• Module must remain in a disabled mode for 3ms after any changes to the variables below to allow sufficient time to commit changes to EEPROM.  
FUNCTIONAL  
REPORTING  
RANGE  
ACCURACY  
(RATED RANGE)  
DEFAULT  
ATTRIBUTE  
PMBusTM COMMAND  
CONDITIONS / NOTES  
VALUE  
100%  
100%  
100%  
100%  
100%  
100%  
100%  
0 ms  
HI Side Overvoltage  
Protection Limit  
VHI_OVLO- is automatically 3%  
lower than this setpoint  
(55h) VIN_OV_FAULT_LIMIT  
(57h) VIN_OV_WARN_LIMIT  
(D7h) DISABLE_FAULTS  
(5Bh) IIN_OC_FAULT_LIMIT  
(5Dh) IIN_OC_WARN_LIMIT  
(4Fh) OT_FAULT_LIMIT  
5%(LL - HL)  
5%(LL - HL)  
5%(LL - HL)  
130V to 435V  
130V to 435V  
130V to 260V  
0 to 5.25A  
HI Side Overvoltage  
Warning Limit  
HI Side Undervoltage  
Protection Limit  
Can only be disabled to a preset  
default value  
HI Side Overcurrent  
Protection Limit  
20%(10 - 20% of FL)  
5%(20 - 133% of FL)  
HI Side Overcurrent  
Warning Limit  
20%(10 - 20% of FL)  
5%(20 - 133% of FL)  
0 to 5.25A  
Overtemperature  
Protection Limit  
Internal Temperature  
Internal Temperature  
7°C(Full Range)  
7°C( Full Range)  
50µs  
0 to 125°C  
0 to 125°C  
0 to 100ms  
Overtemperature  
Warning Limit  
(51h) OT_WARN_LIMIT  
(60h) TON_DELAY  
Additional time delay to the  
Undervoltage Startup Delay  
Turn on Delay  
BCM® in a VIA Package  
Page 10 of 42  
Rev 1.5  
10/2016  
vicorpower.com  
800 927.9474  