BCM4414xD1E13A2yzz
PMBus™ Reported Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of -40°C ≤ TCASE
≤100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
Monitored Telemetry
ACCURACY
(RATED RANGE)
FUNCTIONAL
REPORTING RANGE
UPDATE
RATE
ATTRIBUTE
PMBusTM READ COMMAND
REPORTED UNITS
HI Side Voltage
HI Side Current
LO Side Voltage[1]
LO Side Current
LO Side Resistance
Temperature[2]
(88h) READ_VIN
(89h) READ_IIN
5%(LL - HL)
130V to 450V
-0.85A to 5.9A
4.25V to 14V
100µs
100µs
100µs
100µs
100ms
100ms
VACTUAL = VREPORTED x 10-1
IACTUAL = IREPORTED x 10-3
VACTUAL = VREPORTED x 10-1
IACTUAL = IREPORTED x 10-2
RACTUAL = RREPORTED x 10-5
TACTUAL = TREPORTED
20%(10 - 20% of FL)
5%(20 - 133% of FL)
(8Bh) READ_VOUT
5%(LL - HL)
20%(10 - 20% of FL)
5%(20 - 133% of FL)
(8Ch) READ_IOUT
-27A to 190A
5%(50 - 100% of FL) at NL
10%(50 - 100% of FL)(LL - HL)
(D4h) READ_ROUT
1.0mΩ to 3.0mΩ
- 55ºC to 130ºC
(8Dh) READ_TEMPERATURE_1
7°C(Full Range)
[1] Default READ LO Side Voltage returned when unit is disabled = -300V.
[2] Default READ Temperature returned when unit is disabled = -273°C.
Variable Parameters
• Factory setting of all Thresholds and Warning limits listed below are 100% of specified protection values.
• Variables can be written only when module is disabled with VHI < VHI_UVLO- and external bias (VDDB) applied.
• Module must remain in a disabled mode for 3ms after any changes to the variables below to allow sufficient time to commit changes to EEPROM.
FUNCTIONAL
REPORTING
RANGE
ACCURACY
(RATED RANGE)
DEFAULT
ATTRIBUTE
PMBusTM COMMAND
CONDITIONS / NOTES
VALUE
100%
100%
100%
100%
100%
100%
100%
0 ms
HI Side Overvoltage
Protection Limit
VHI_OVLO- is automatically 3%
lower than this setpoint
(55h) VIN_OV_FAULT_LIMIT
(57h) VIN_OV_WARN_LIMIT
(D7h) DISABLE_FAULTS
(5Bh) IIN_OC_FAULT_LIMIT
(5Dh) IIN_OC_WARN_LIMIT
(4Fh) OT_FAULT_LIMIT
5%(LL - HL)
5%(LL - HL)
5%(LL - HL)
130V to 435V
130V to 435V
130V to 260V
0 to 5.25A
HI Side Overvoltage
Warning Limit
HI Side Undervoltage
Protection Limit
Can only be disabled to a preset
default value
HI Side Overcurrent
Protection Limit
20%(10 - 20% of FL)
5%(20 - 133% of FL)
HI Side Overcurrent
Warning Limit
20%(10 - 20% of FL)
5%(20 - 133% of FL)
0 to 5.25A
Overtemperature
Protection Limit
Internal Temperature
Internal Temperature
7°C(Full Range)
7°C( Full Range)
50µs
0 to 125°C
0 to 125°C
0 to 100ms
Overtemperature
Warning Limit
(51h) OT_WARN_LIMIT
(60h) TON_DELAY
Additional time delay to the
Undervoltage Startup Delay
Turn on Delay
BCM® in a VIA Package
Page 10 of 42
Rev 1.5
10/2016
vicorpower.com